EconPapers    
Economics at your fingertips  
 

Model-Based Water Wall Fault Detection and Diagnosis of FBC Boiler Using Strong Tracking Filter

Li Sun, Junyi Dong, Donghai Li and Yuqiong Zhang

Mathematical Problems in Engineering, 2014, vol. 2014, 1-8

Abstract:

Fluidized bed combustion (FBC) boilers have received increasing attention in recent decades. The erosion issue on the water wall is one of the most common and serious faults for FBC boilers. Unlike direct measurement of tube thickness used by ultrasonic methods, the wastage of water wall is reconsidered equally as the variation of the overall heat transfer coefficient in the furnace. In this paper, a model-based approach is presented to estimate internal states and heat transfer coefficient dually from the noisy measurable outputs. The estimated parameter is compared with the normal value. Then the modified Bayesian algorithm is adopted for fault detection and diagnosis (FDD). The simulation results demonstrate that the approach is feasible and effective.

Date: 2014
References: Add references at CitEc
Citations:

Downloads: (external link)
http://downloads.hindawi.com/journals/MPE/2014/504086.pdf (application/pdf)
http://downloads.hindawi.com/journals/MPE/2014/504086.xml (text/xml)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:hin:jnlmpe:504086

DOI: 10.1155/2014/504086

Access Statistics for this article

More articles in Mathematical Problems in Engineering from Hindawi
Bibliographic data for series maintained by Mohamed Abdelhakeem ().

 
Page updated 2025-03-19
Handle: RePEc:hin:jnlmpe:504086