Heteroepitaxial passivation of Cs2AgBiBr6 wafers with suppressed ionic migration for X-ray imaging
Bo Yang,
Weicheng Pan,
Haodi Wu,
Guangda Niu (),
Jun-Hui Yuan,
Kan-Hao Xue,
Lixiao Yin,
Xinyuan Du,
Xiang-Shui Miao,
Xiaoquan Yang,
Qingguo Xie and
Jiang Tang ()
Additional contact information
Bo Yang: Huazhong University of Science and Technology (HUST)
Weicheng Pan: Huazhong University of Science and Technology (HUST)
Haodi Wu: Huazhong University of Science and Technology (HUST)
Guangda Niu: Huazhong University of Science and Technology (HUST)
Jun-Hui Yuan: Huazhong University of Science and Technology (HUST)
Kan-Hao Xue: Huazhong University of Science and Technology (HUST)
Lixiao Yin: Huazhong University of Science and Technology (HUST)
Xinyuan Du: Huazhong University of Science and Technology (HUST)
Xiang-Shui Miao: Huazhong University of Science and Technology (HUST)
Xiaoquan Yang: Huazhong University of Science and Technology (HUST)
Qingguo Xie: Huazhong University of Science and Technology (HUST)
Jiang Tang: Huazhong University of Science and Technology (HUST)
Nature Communications, 2019, vol. 10, issue 1, 1-10
Abstract:
Abstract X-ray detectors are broadly utilized in medical imaging and product inspection. Halide perovskites recently demonstrate excellent performance for direct X-ray detection. However, ionic migration causes large noise and baseline drift, limiting the detection and imaging performance. Here we largely eliminate the ionic migration in cesium silver bismuth bromide (Cs2AgBiBr6) polycrystalline wafers by introducing bismuth oxybromide (BiOBr) as heteroepitaxial passivation layers. Good lattice match between BiOBr and Cs2AgBiBr6 enables complete defect passivation and suppressed ionic migration. The detector hence achieves outstanding balanced performance with a signal drifting one order of magnitude lower than all previous studies, low noise (1/f noise free), a high sensitivity of 250 µC Gy air−1 cm–2, and a spatial resolution of 4.9 lp mm−1. The wafer area could be easily scaled up by the isostatic-pressing method, together with the heteroepitaxial passivation, strengthens the competitiveness of Cs2AgBiBr6-based X-ray detectors as next-generation X-ray imaging flat panels.
Date: 2019
References: Add references at CitEc
Citations: View citations in EconPapers (1)
Downloads: (external link)
https://www.nature.com/articles/s41467-019-09968-3 Abstract (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:nat:natcom:v:10:y:2019:i:1:d:10.1038_s41467-019-09968-3
Ordering information: This journal article can be ordered from
https://www.nature.com/ncomms/
DOI: 10.1038/s41467-019-09968-3
Access Statistics for this article
Nature Communications is currently edited by Nathalie Le Bot, Enda Bergin and Fiona Gillespie
More articles in Nature Communications from Nature
Bibliographic data for series maintained by Sonal Shukla () and Springer Nature Abstracting and Indexing ().