EconPapers    
Economics at your fingertips  
 

Early screening of lung function by electrical impedance tomography in people with normal spirometry reveals unrecognized pathological features

Shuoyao Qu, Enzhi Feng, Daihan Dong, Lin Yang (), Meng Dai, Inéz Frerichs, Shaojie Liu, Yi Gao, Jinping Zheng, Liqiang Song () and Zhanqi Zhao ()
Additional contact information
Shuoyao Qu: Air Force Medical University
Enzhi Feng: No. 941 Hospital of the Joint Support Force of People’s Liberation Army (PLA)
Daihan Dong: Air Force Medical University
Lin Yang: Air Force Medical University
Meng Dai: Air Force Medical University
Inéz Frerichs: University Medical Center of Schleswig-Holstein Campus Kiel
Shaojie Liu: No. 941 Hospital of the Joint Support Force of People’s Liberation Army (PLA)
Yi Gao: First Affiliated Hospital of Guangzhou Medical University
Jinping Zheng: First Affiliated Hospital of Guangzhou Medical University
Liqiang Song: Air Force Medical University
Zhanqi Zhao: First Affiliated Hospital of Guangzhou Medical University

Nature Communications, 2025, vol. 16, issue 1, 1-9

Abstract: Abstract Early detection of lung function impairment is crucial. However, the sensitivity of spirometry in detecting early lung function deterioration is limited. In this study, lungs of 3180 healthy participants scheduled for annual health check were screened. Electrical impedance tomography measurements were conducted in 130 participants with normal spirometry for concept establishment phase and 105 for validation phase. A follow-up CT examination was suggested for participants with abnormal regional time constant or tobacco consumption ≥10 pack-years. Using CT as reference, the sensitivity and specificity of electrical impedance tomography-based screening were 81.3% and 50.0%, respectively in the concept establishment phase. In the validation phase, the sensitivity and specificity were 77.9% and 50.0%. In this study we show that conventional spirometry may not capture early changes that occur at a regional level. The regional time constant based on electrical impedance tomography can be a promising tool for early screening of lung function impairment. Clinical trial registration: ChiCTR2300076673, www.chictr.org.cn .

Date: 2025
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.nature.com/articles/s41467-024-55505-2 Abstract (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:nat:natcom:v:16:y:2025:i:1:d:10.1038_s41467-024-55505-2

Ordering information: This journal article can be ordered from
https://www.nature.com/ncomms/

DOI: 10.1038/s41467-024-55505-2

Access Statistics for this article

Nature Communications is currently edited by Nathalie Le Bot, Enda Bergin and Fiona Gillespie

More articles in Nature Communications from Nature
Bibliographic data for series maintained by Sonal Shukla () and Springer Nature Abstracting and Indexing ().

 
Page updated 2025-03-19
Handle: RePEc:nat:natcom:v:16:y:2025:i:1:d:10.1038_s41467-024-55505-2