Multivariate metal-organic frameworks enable chemical shift-encoded MRI with femtomolar sensitivity for biological systems
Qingbin Zeng,
Quer Yue,
Ming Zhang,
Rui Zhou,
Zhen Wang,
Zhongyu Xiao,
Yaping Yuan,
Xiuchao Zhao,
Weiping Jiang,
Lei Zhang,
Yuqi Yang,
Minghui Yang,
Haidong Li,
Louis-S. Bouchard,
Qianni Guo () and
Xin Zhou ()
Additional contact information
Qingbin Zeng: Innovation Academy for Precision Measurement Science and Technology
Quer Yue: Innovation Academy for Precision Measurement Science and Technology
Ming Zhang: Innovation Academy for Precision Measurement Science and Technology
Rui Zhou: Innovation Academy for Precision Measurement Science and Technology
Zhen Wang: Innovation Academy for Precision Measurement Science and Technology
Zhongyu Xiao: Innovation Academy for Precision Measurement Science and Technology
Yaping Yuan: Innovation Academy for Precision Measurement Science and Technology
Xiuchao Zhao: Innovation Academy for Precision Measurement Science and Technology
Weiping Jiang: Innovation Academy for Precision Measurement Science and Technology
Lei Zhang: Innovation Academy for Precision Measurement Science and Technology
Yuqi Yang: Innovation Academy for Precision Measurement Science and Technology
Minghui Yang: Innovation Academy for Precision Measurement Science and Technology
Haidong Li: Innovation Academy for Precision Measurement Science and Technology
Louis-S. Bouchard: University of California
Qianni Guo: Innovation Academy for Precision Measurement Science and Technology
Xin Zhou: Innovation Academy for Precision Measurement Science and Technology
Nature Communications, 2025, vol. 16, issue 1, 1-13
Abstract:
Abstract Fluorescent molecules with specific target moieties are essential for histopathological analysis, but their limited tissue penetration depth makes in vivo, in situ color encoding analysis challenging. Magnetic resonance imaging (MRI) offers deep tissue penetration. When combined with chemical shift-encoded MRI reporters, it enables in vivo chemical shift encoding for biotarget imaging and analysis. These reporters require both strong signal intensity and large chemical shift window. However, conventional proton MRI reporters, with low sensitivity and a small chemical shift window, limit their in vivo applications. Here, we describe a chemical shift-encoded hyperpolarized 129Xe MRI reporter based on the multivariate metal-organic framework, NiZn-ZIF-8, to overcome these challenges. The proposed NiZn-ZIF-8 gives distinct chemical shifts for dissolved and entrapped 129Xe without signal interference, enhancing the 129Xe NMR signal by 210 times compared to dissolved 129Xe in water and biological media. This enables detection threshold at ≈ 4 fM concentrations, setting a record for the lowest concentration of xenon hosts detected in nanomaterials. Additionally, NiZn-ZIF-8 exhibits good in vivo MRI performance, allowing xenon encoding and distinction in rat lungs. NiZn-ZIF-8 represents a versatile and powerful platform for advanced molecular imaging and in vivo biomedical diagnostics.
Date: 2025
References: Add references at CitEc
Citations:
Downloads: (external link)
https://www.nature.com/articles/s41467-025-62110-4 Abstract (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:nat:natcom:v:16:y:2025:i:1:d:10.1038_s41467-025-62110-4
Ordering information: This journal article can be ordered from
https://www.nature.com/ncomms/
DOI: 10.1038/s41467-025-62110-4
Access Statistics for this article
Nature Communications is currently edited by Nathalie Le Bot, Enda Bergin and Fiona Gillespie
More articles in Nature Communications from Nature
Bibliographic data for series maintained by Sonal Shukla () and Springer Nature Abstracting and Indexing ().