Liquid-state carbon-13 hyperpolarization generated in an MRI system for fast imaging
A. B. Schmidt,
S. Berner,
W. Schimpf,
C. Müller,
T. Lickert,
N. Schwaderlapp,
S. Knecht,
J. G. Skinner,
A. Dost,
P. Rovedo,
J. Hennig,
D. von Elverfeldt and
J. -B. Hövener ()
Additional contact information
A. B. Schmidt: Medical Physics, Medical Center—University of Freiburg, Faculty of Medicine, University of Freiburg
S. Berner: Medical Physics, Medical Center—University of Freiburg, Faculty of Medicine, University of Freiburg
W. Schimpf: Medical Physics, Medical Center—University of Freiburg, Faculty of Medicine, University of Freiburg
C. Müller: Medical Physics, Medical Center—University of Freiburg, Faculty of Medicine, University of Freiburg
T. Lickert: Fraunhofer Institute for Solar Energy Systems (ISE)
N. Schwaderlapp: Medical Physics, Medical Center—University of Freiburg, Faculty of Medicine, University of Freiburg
S. Knecht: Medical Physics, Medical Center—University of Freiburg, Faculty of Medicine, University of Freiburg
J. G. Skinner: Medical Physics, Medical Center—University of Freiburg, Faculty of Medicine, University of Freiburg
A. Dost: Medical Physics, Medical Center—University of Freiburg, Faculty of Medicine, University of Freiburg
P. Rovedo: Medical Physics, Medical Center—University of Freiburg, Faculty of Medicine, University of Freiburg
J. Hennig: Medical Physics, Medical Center—University of Freiburg, Faculty of Medicine, University of Freiburg
D. von Elverfeldt: Medical Physics, Medical Center—University of Freiburg, Faculty of Medicine, University of Freiburg
J. -B. Hövener: Medical Physics, Medical Center—University of Freiburg, Faculty of Medicine, University of Freiburg
Nature Communications, 2017, vol. 8, issue 1, 1-8
Abstract:
Abstract Hyperpolarized (HP) tracers dramatically increase the sensitivity of magnetic resonance imaging (MRI) to monitor metabolism non-invasively and in vivo. Their production, however, requires an extra polarizing device (polarizer) whose complexity, operation and cost can exceed that of an MRI system itself. Furthermore, the lifetime of HP tracers is short and some of the enhancement is lost during transfer to the application site. Here, we present the production of HP tracers in water without an external polarizer: by Synthesis Amid the Magnet Bore, A Dramatically Enhanced Nuclear Alignment (SAMBADENA) is achieved within seconds, corresponding to a hyperpolarization of ∼20%. As transfer of the tracer is no longer required, SAMBADENA may permit a higher polarization at the time of detection at a fraction of the cost and complexity of external polarizers. This development is particularly promising in light of the recently extended portfolio of biomedically relevant para-hydrogen-tracers and may lead to new diagnostic applications.
Date: 2017
References: Add references at CitEc
Citations:
Downloads: (external link)
https://www.nature.com/articles/ncomms14535 Abstract (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:nat:natcom:v:8:y:2017:i:1:d:10.1038_ncomms14535
Ordering information: This journal article can be ordered from
https://www.nature.com/ncomms/
DOI: 10.1038/ncomms14535
Access Statistics for this article
Nature Communications is currently edited by Nathalie Le Bot, Enda Bergin and Fiona Gillespie
More articles in Nature Communications from Nature
Bibliographic data for series maintained by Sonal Shukla () and Springer Nature Abstracting and Indexing ().