Accuracy of rapid point-of-care antigen-based diagnostics for SARS-CoV-2: An updated systematic review and meta-analysis with meta-regression analyzing influencing factors
Lukas E Brümmer,
Stephan Katzenschlager,
Sean McGrath,
Stephani Schmitz,
Mary Gaeddert,
Christian Erdmann,
Marc Bota,
Maurizio Grilli,
Jan Larmann,
Markus A Weigand,
Nira R Pollock,
Aurélien Macé,
Berra Erkosar,
Sergio Carmona,
Jilian A Sacks,
Stefano Ongarello and
Claudia M Denkinger
PLOS Medicine, 2022, vol. 19, issue 5, 1-34
Abstract:
Background: Comprehensive information about the accuracy of antigen rapid diagnostic tests (Ag-RDTs) for Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) is essential to guide public health decision makers in choosing the best tests and testing policies. In August 2021, we published a systematic review and meta-analysis about the accuracy of Ag-RDTs. We now update this work and analyze the factors influencing test sensitivity in further detail. Methods and findings: We registered the review on PROSPERO (registration number: CRD42020225140). We systematically searched preprint and peer-reviewed databases for publications evaluating the accuracy of Ag-RDTs for SARS-CoV-2 until August 31, 2021. Descriptive analyses of all studies were performed, and when more than 4 studies were available, a random-effects meta-analysis was used to estimate pooled sensitivity and specificity with reverse transcription polymerase chain reaction (RT-PCR) testing as a reference. To evaluate factors influencing test sensitivity, we performed 3 different analyses using multivariable mixed-effects meta-regression models. We included 194 studies with 221,878 Ag-RDTs performed. Overall, the pooled estimates of Ag-RDT sensitivity and specificity were 72.0% (95% confidence interval [CI] 69.8 to 74.2) and 98.9% (95% CI 98.6 to 99.1). When manufacturer instructions were followed, sensitivity increased to 76.3% (95% CI 73.7 to 78.7). Sensitivity was markedly better on samples with lower RT-PCR cycle threshold (Ct) values (97.9% [95% CI 96.9 to 98.9] and 90.6% [95% CI 88.3 to 93.0] for Ct-values 90%) when high viral loads are present. With viral load, as estimated by Ct-value, being the most influential factor on their sensitivity, they are especially useful to detect persons with high viral load who are most likely to transmit the virus. To further quantify the effects of other factors influencing test sensitivity, standardization of clinical accuracy studies and access to patient level Ct-values and duration of symptoms are needed. Lukas Brümmer and co-workers report an updated systematic review and meta-analysis on the accuracy of antigen-based rapid diagnostic tests for SARS-CoV-2 infection.Why was this study done?: What did the researchers do and find?: What do these findings mean?:
Date: 2022
References: Add references at CitEc
Citations:
Downloads: (external link)
https://journals.plos.org/plosmedicine/article?id=10.1371/journal.pmed.1004011 (text/html)
https://journals.plos.org/plosmedicine/article/fil ... 04011&type=printable (application/pdf)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:plo:pmed00:1004011
DOI: 10.1371/journal.pmed.1004011
Access Statistics for this article
More articles in PLOS Medicine from Public Library of Science
Bibliographic data for series maintained by plosmedicine ().