Seroconverting Blood Donors as a Resource for Characterising and Optimising Recent Infection Testing Algorithms for Incidence Estimation
Reshma Kassanjee,
Alex Welte,
Thomas A McWalter,
Sheila M Keating,
Marion Vermeulen,
Susan L Stramer and
Michael P Busch
PLOS ONE, 2011, vol. 6, issue 6, 1-8
Abstract:
Introduction: Biomarker-based cross-sectional incidence estimation requires a Recent Infection Testing Algorithm (RITA) with an adequately large mean recency duration, to achieve reasonable survey counts, and a low false-recent rate, to minimise exposure to further bias and imprecision. Estimating these characteristics requires specimens from individuals with well-known seroconversion dates or confirmed long-standing infection. Specimens with well-known seroconversion dates are typically rare and precious, presenting a bottleneck in the development of RITAs. Methods: The mean recency duration and a ‘false-recent rate’ are estimated from data on seroconverting blood donors. Within an idealised model for the dynamics of false-recent results, blood donor specimens were used to characterise RITAs by a new method that maximises the likelihood of cohort-level recency classifications, rather than modelling individual sojourn times in recency. Results: For a range of assumptions about the false-recent results (0% to 20% of biomarker response curves failing to reach the threshold distinguishing test-recent and test-non-recent infection), the mean recency duration of the Vironostika-LS ranged from 154 (95% CI: 96–231) to 274 (95% CI: 234–313) days in the South African donor population (n = 282), and from 145 (95% CI: 67–226) to 252 (95% CI: 194–308) days in the American donor population (n = 106). The significance of gender and clade on performance was rejected (p−value = 10%), and utility in incidence estimation appeared comparable to that of a BED-like RITA. Assessment of the Vitros-LS (n = 108) suggested potentially high false-recent rates. Discussion: The new method facilitates RITA characterisation using widely available specimens that were previously overlooked, at the cost of possible artefacts. While accuracy and precision are insufficient to provide estimates suitable for incidence surveillance, a low-cost approach for preliminary assessments of new RITAs has been demonstrated. The Vironostika-LS and Vitros-LS warrant further analysis to provide greater precision of estimates.
Date: 2011
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0020027 (text/html)
https://journals.plos.org/plosone/article/file?id= ... 20027&type=printable (application/pdf)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:plo:pone00:0020027
DOI: 10.1371/journal.pone.0020027
Access Statistics for this article
More articles in PLOS ONE from Public Library of Science
Bibliographic data for series maintained by plosone ().