Simultaneous Immunoassay Analysis of Plasma IL-6 and TNF-α on a Microchip

Kaori Abe, Yoshiko Hashimoto, Shouki Yatsushiro, Shohei Yamamura, Mika Bando, Yuka Hiroshima, Jun-ichi Kido, Masato Tanaka, Yasuo Shinohara, Toshihiko Ooie, Yoshinobu Baba and Masatoshi Kataoka

PLOS ONE, 2013, vol. 8, issue 1, 1-8

Abstract: Sandwich enzyme-linked immunosorbant assay (ELISA) using a 96-well plate is frequently employed for clinical diagnosis, but is time-and sample-consuming. To overcome these drawbacks, we performed a sandwich ELISA on a microchip. The microchip was made of cyclic olefin copolymer with 4 straight microchannels. For the construction of the sandwich ELISA for interleukin-6 (IL-6) or tumor necrosis factor-α (TNF-α), we used a piezoelectric inkjet printing system for the deposition and fixation of the 1st anti-IL-6 antibody or 1st anti-TNF-α antibody on the surface of the each microchannel. After the infusion of 2 µl of sample to the microchannel and a 20 min incubation, 2 µl of biotinylated 2nd antibody for either antigen was infused and a 10 min incubation. Then 2 µl of avidin-horseradish peroxidase was infused; and after a 5 min incubation, the substrate for peroxidase was infused, and the luminescence intensity was measured. Calibration curves were obtained between the concentration and luminescence intensity over the range of 0 to 32 pg/ml (IL-6: R2 = 0.9994, TNF-α: R2 = 0.9977), and the detection limit for each protein was 0.28 pg/ml and 0.46 pg/ml, respectively. Blood IL-6 and TNF-α concentrations of 5 subjects estimated from the microchip data were compared with results obtained by the conventional method, good correlations were observed between the methods according to linear regression analysis (IL-6: R2 = 0.9954, TNF-α: R2 = 0.9928). The reproducibility of the presented assay for the determination of the blood IL-6 and TNF-α concentration was comparable to that obtained with the 96-well plate. Simultaneous detection of blood IL-6 and TNF-α was possible by the deposition and fixation of each 1st antibody on the surface of a separate microchannel. This assay enabled us to determine simultaneously blood IL-6 and TNF-α with accuracy, satisfactory sensitivity, time saving ability, and low consumption of sample and reagents, and will be applicable to clinic diagnosis.

Date: 2013
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0053620 (text/html)
https://journals.plos.org/plosone/article/file?id= ... 53620&type=printable (application/pdf)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:plo:pone00:0053620

DOI: 10.1371/journal.pone.0053620