Comparison of Manual and Automated Preprocedural Segmentation Tools to Predict the Annulus Plane Angulation and C-Arm Positioning for Transcatheter Aortic Valve Replacement
Verena Veulemans,
Tobias Zeus,
Laura Kleinebrecht,
Jan Balzer,
Katharina Hellhammer,
Amin Polzin,
Patrick Horn,
Alexander Blehm,
Jan-Philipp Minol,
Patric Kröpil,
Ralf Westenfeld,
Tienush Rassaf,
Artur Lichtenberg and
Malte Kelm
PLOS ONE, 2016, vol. 11, issue 4, 1-14
Abstract:
Background: Preprocedural manual multi-slice-CT-segmentation tools (MSCT-ST) define the gold standard for planning transcatheter aortic valve replacement (TAVR). They are able to predict the perpendicular line of the aortic annulus (PPL) and to indicate the corresponding C-arm angulation (CAA). Fully automated planning-tools and their clinical relevance have not been systematically evaluated in a real world setting so far. Methods and Results: The study population consists of an all-comers cohort of 160 consecutive TAVR patients with a drop out of 35 patients for technical and anatomical reasons. 125 TAVR patients underwent preprocedural analysis by manual (M-MSCT) and fully automated MSCT-ST (A-MSCT). Method-comparison was performed for 105 patients (Cohort A). In Cohort A, CAA was defined for each patient, and accordance within 10° between M-MSCT and A-MSCT was considered adequate for concept-proof (95% in LAO/RAO; 94% in CRAN/CAUD). Intraprocedural CAA was defined by repetitive angiograms without utilizing the preprocedural measurements. In Cohort B, intraprocedural CAA was established with the use of A-MSCT (20 patients). Using preprocedural A-MSCT to indicate the corresponding CAA, the levels of contrast medium (ml) and radiation exposure (cine runs) were reduced in Cohort B compared to Cohort A significantly (23.3±10.3 vs. 35.3 ±21.1 ml, p = 0.02; 1.6±0.7 vs. 2.4±1.4 cine runs; p = 0.02) and trends towards more safety in valve-positioning could be demonstrated. Conclusions: A-MSCT-analysis provides precise preprocedural information on CAA for optimal visualization of the aortic annulus compared to the M-MSCT gold standard. Intraprocedural application of this information during TAVR significantly reduces the levels of contrast and radiation exposure. Trial Registration: ClinicalTrials.gov NCT01805739
Date: 2016
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0151918 (text/html)
https://journals.plos.org/plosone/article/file?id= ... 51918&type=printable (application/pdf)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:plo:pone00:0151918
DOI: 10.1371/journal.pone.0151918
Access Statistics for this article
More articles in PLOS ONE from Public Library of Science
Bibliographic data for series maintained by plosone ().