EconPapers    
Economics at your fingertips  
 

Test-Retest Reliability of 10 Hz Conditioning Electrical Stimulation Inducing Long-Term Potentiation (LTP)-Like Pain Amplification in Humans

Weiwei Xia, Carsten Dahl Mørch and Ole Kæseler Andersen

PLOS ONE, 2016, vol. 11, issue 8, 1-18

Abstract: Background: 10 Hz conditioning electrical stimulation (CES) has been shown to induce long-term potentiation (LTP)-like pain amplification similar to traditional 100 Hz CES in healthy humans. The aim of this study was to assess the test-retest reliability and to estimate sample sizes required for future crossover and parallel study designs. Methods: The 10 Hz paradigm (500 rectangular pulses lasting 50 s) was repeated on two separate days with one week interval in twenty volunteers. Perceptual intensities to single electrical stimulation (SES) at the conditioned skin site and to mechanical stimuli (pinprick and light stroking) in immediate vicinity to the conditioned skin site were recorded. Superficial blood flow (SBF) was assessed as indicator of neurogenic inflammation. All outcome measures were assessed with 10 min interval three times before and six times after the CES. The coefficient of variation and intra-class correlation coefficient were calculated within session and between sessions. Sample sizes were estimated for future crossover (Ncr) and parallel (Np) drug testing studies expected to detect a 30% decrease for the individual outcome measure following 10 Hz CES. Results: Perceptual intensity ratings to light stroking (Ncr = 2, Np = 33) and pinprick stimulation (491 mN) (Ncr = 6, Np = 54) increased after CES and showed better reliability in crossover than parallel design. The SBF increased after CES, and then declined until reaching a plateau 20 minutes postCES. SBF showed acceptable reliability both in crossover and parallel designs (Ncr = 3, Np = 13). Pain ratings to SES were reliable, but with large estimated sample sizes (Ncr = 634, Np = 11310) due to the minor pain amplification. Conclusions: The reliability of 10 Hz CES was acceptable in inducing LTP-like effects in the assessments of superficial blood flow, heterotopic mechanical hyperalgesia, and dysesthesia in terms of sample sizes for future crossover study designs.

Date: 2016
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0161117 (text/html)
https://journals.plos.org/plosone/article/file?id= ... 61117&type=printable (application/pdf)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:plo:pone00:0161117

DOI: 10.1371/journal.pone.0161117

Access Statistics for this article

More articles in PLOS ONE from Public Library of Science
Bibliographic data for series maintained by plosone ().

 
Page updated 2025-03-29
Handle: RePEc:plo:pone00:0161117