EZSCAN for undiagnosed type 2 diabetes mellitus: A systematic review and meta-analysis
Antonio Bernabe-Ortiz,
Andrea Ruiz-Alejos,
J Jaime Miranda,
Rohini Mathur,
Pablo Perel and
Liam Smeeth
PLOS ONE, 2017, vol. 12, issue 10, 1-11
Abstract:
Objectives: The EZSCAN is a non-invasive device that, by evaluating sweat gland function, may detect subjects with type 2 diabetes mellitus (T2DM). The aim of the study was to conduct a systematic review and meta-analysis including studies assessing the performance of the EZSCAN for detecting cases of undiagnosed T2DM. Methodology/Principal findings: We searched for observational studies including diagnostic accuracy and performance results assessing EZSCAN for detecting cases of undiagnosed T2DM. OVID (Medline, Embase, Global Health), CINAHL and SCOPUS databases, plus secondary resources, were searched until March 29, 2017. The following keywords were utilized for the systematic searching: type 2 diabetes mellitus, hyperglycemia, EZSCAN, SUDOSCAN, and sudomotor function. Two investigators extracted the information for meta-analysis and assessed the quality of the data using the Revised Version of the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist. Pooled estimates were obtained by fitting the logistic-normal random-effects model without covariates but random intercepts and using the Freeman-Tukey Arcsine Transformation to stabilize variances. Heterogeneity was also assessed using the I2 measure. Four studies (n = 7,720) were included, three of them used oral glucose tolerance test as the gold standard. Using Hierarchical Summary Receiver Operating Characteristic model, summary sensitivity was 72.0% (95%CI: 60.0%– 83.0%), whereas specificity was 56.0% (95%CI: 38.0%– 74.0%). Studies were very heterogeneous (I2 for sensitivity: 79.2% and for specificity: 99.1%) regarding the inclusion criteria and bias was present mainly due to participants selection. Conclusions: The sensitivity of EZSCAN for detecting cases of undiagnosed T2DM seems to be acceptable, but evidence of high heterogeneity and participant selection bias was detected in most of the studies included. More studies are needed to evaluate the performance of the EZSCAN for undiagnosed T2DM screening, especially at the population level.
Date: 2017
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0187297 (text/html)
https://journals.plos.org/plosone/article/file?id= ... 87297&type=printable (application/pdf)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:plo:pone00:0187297
DOI: 10.1371/journal.pone.0187297
Access Statistics for this article
More articles in PLOS ONE from Public Library of Science
Bibliographic data for series maintained by plosone ().