Increasing sensitivity of methane emission measurements in rice through deployment of ‘closed chambers’ at nighttime
Reiner Wassmann,
Ma Carmelita Alberto,
Agnes Tirol-Padre,
Nghia Trong Hoang,
Ryan Romasanta,
Caesar Arloo Centeno and
Bjoern Ole Sander
PLOS ONE, 2018, vol. 13, issue 2, 1-16
Abstract:
This study comprises field experiments on methane emissions from rice fields conducted with an Eddy-Covariance (EC) system as well as test runs for a modified closed chamber approach based on measurements at nighttime. The EC data set covers 4 cropping seasons with highly resolved emission rates (raw data in 10 Hz frequency have been aggregated to 30-min records). The diel patterns were very pronounced in the two dry seasons with peak emissions at early afternoon and low emissions at nighttime. These diel patterns were observed at all growing stages of the dry seasons. In the two wet seasons, the diel patterns were only visible during the vegetative stages while emission rates during reproductive and ripening stages remained within a fairly steady range and did not show any diel patterns. In totality, however, the data set revealed a very strong linear relationship between nocturnal emissions (12-h periods) and the full 24-h periods resulting in an R2-value of 0.8419 for all data points. In the second experiment, we conducted test runs for chamber measurements at nighttime with much longer deployment times (6 h) as compared to measurements at daylight (typically for 30 min). Conducting chamber measurements at nighttime excluded drastic changes of temperatures and CO2 concentrations. The data also shows that increases in CH4 concentrations remained on linear trajectory over a 6h period at night. While end CH4 concentrations were consistently >3.5 ppm, this long-term enclosure represents a very robust approach to quantify emissions as compared to assessing short-term concentration increases over time near the analytical detection limit. Finally, we have discussed the potential applications of this new approach that would allow emission measurements even when conventional (daytime) measurements will not be suitable. Nighttime chamber measurements offer an alternative to conventional (daytime) measurements if either (i) baseline emissions are at a very low level, (ii) differences of tested crop treatments or varieties are very small or (iii) the objective is to screen a large number of rice varieties for taking advantage of progress in genome sequencing.
Date: 2018
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0191352 (text/html)
https://journals.plos.org/plosone/article/file?id= ... 91352&type=printable (application/pdf)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:plo:pone00:0191352
DOI: 10.1371/journal.pone.0191352
Access Statistics for this article
More articles in PLOS ONE from Public Library of Science
Bibliographic data for series maintained by plosone ().