EconPapers    
Economics at your fingertips  
 

Identifying bedrest using 24-h waist or wrist accelerometry in adults

J Tracy, Sari Acra, Kong Y Chen and Maciej S Buchowski

PLOS ONE, 2018, vol. 13, issue 3, 1-16

Abstract: Objectives: To adapt and refine a previously-developed youth-specific algorithm to identify bedrest for use in adults. The algorithm is based on using an automated decision tree (DT) analysis of accelerometry data. Design: Healthy adults (n = 141, 85 females, 19–69 years-old) wore accelerometers on the waist, with a subset also wearing accelerometers on the dominant wrist (n = 45). Participants spent ≈24-h in a whole-room indirect calorimeter equipped with a force-platform floor to detect movement. Methods: Minute-by-minute data from recordings of waist-worn or wrist-worn accelerometers were used to identify bedrest and wake periods. Participants were randomly allocated to development (n = 69 and 23) and validation (n = 72 and 22) groups for waist-worn and wrist-worn accelerometers, respectively. The optimized DT algorithm parameters were block length, threshold, bedrest-start trigger, and bedrest-end trigger. Differences between DT classification and synchronized objective classification by the room calorimeter to bedrest or wake were assessed for sensitivity, specificity, and accuracy using a Receiver Operating Characteristic (ROC) procedure applied to 1-min epochs (n = 92,543 waist; n = 30,653 wrist). Results: The optimal algorithm parameter values for block length were 60 and 45 min, thresholds 12.5 and 400 counts/min, bedrest-start trigger 120 and 400 counts/min, and bedrest-end trigger 1,200 and 1,500 counts/min, for the waist and wrist-worn accelerometers, respectively. Bedrest was identified correctly in the validation group with sensitivities of 0.819 and 0.912, specificities of 0.966 and 0.923, and accuracies of 0.755 and 0.859 by the waist and wrist-worn accelerometer, respectively. The DT algorithm identified bedrest/sleep with greater accuracy than a commonly used automated algorithm (Cole-Kripke) for wrist-worn accelerometers (p

Date: 2018
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0194461 (text/html)
https://journals.plos.org/plosone/article/file?id= ... 94461&type=printable (application/pdf)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:plo:pone00:0194461

DOI: 10.1371/journal.pone.0194461

Access Statistics for this article

More articles in PLOS ONE from Public Library of Science
Bibliographic data for series maintained by plosone ().

 
Page updated 2025-03-19
Handle: RePEc:plo:pone00:0194461