Effectiveness of steam sterilization of reusable medical devices in primary and secondary care public hospitals in Nepal and factors associated with ineffective sterilization: A nation-wide cross-sectional study
Gopal Panta,
Ann K Richardson,
Ian C Shaw,
Stephen Chambers and
Patricia A Coope
PLOS ONE, 2019, vol. 14, issue 11, 1-14
Abstract:
Background: Inadequate sterilization of reusable medical devices can lead to healthcare associated infections (HAIs) through person-to-person or environmental transmission of pathogens. Autoclaving (steam sterilization) is most commonly used for sterilizing medical devices in healthcare facilities. We conducted a nation-wide cross-sectional study to evaluate the effectiveness of steam sterilization practices in primary and secondary care public hospitals in Nepal and to identify factors associated with ineffective sterilization. Methods: Using a stratified clustered random sampling, 13 primary- and secondary-care public hospitals in Nepal were selected. 189 steam sterilization cycles from these hospitals were evaluated for their effectiveness using self-contained biological indicators, class-5 chemical indicators, autoclave indicator tape and physical parameters. Information about the hospitals and the types of autoclaves being used was also collected. Data were analysed to estimate the proportion of ineffective steam sterilization cycles. Logistic regression was used to identify factors associated with ineffective sterilization. Findings: In primary and secondary care public hospitals in Nepal, 71.0% (95% CI 46.8% - 87.2%) of the autoclave cycles were ineffective (i.e. showed positive results) when tested with biological indicators and 69.8% (95% CI 44.4% - 87.0%) showed ‘reject’ results with class 5 chemical indicators. There was no statistically significant difference in proportions showing positive or reject results by hospital types for either biological (p = 0.51) or class 5 chemical (p = 0.87) indicators. Autoclave type and pressure achieved during sterilization were statistically significantly associated with steam sterilization failures, adjusted for holding period, evenness of pressure and barrier system used. Conclusion: Primary and secondary care hospitals in Nepal have a high proportion of steam sterilization failure, indicating a risk of person-to-person transmission of pathogens through reusable medical devices. There is an urgent need to improve steam sterilization processes in these hospitals.
Date: 2019
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0225595 (text/html)
https://journals.plos.org/plosone/article/file?id= ... 25595&type=printable (application/pdf)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:plo:pone00:0225595
DOI: 10.1371/journal.pone.0225595
Access Statistics for this article
More articles in PLOS ONE from Public Library of Science