Estimating the impact of differential adherence on the comparative effectiveness of stool-based colorectal cancer screening using the CRC-AIM microsimulation model
Andrew Piscitello,
Leila Saoud,
A Mark Fendrick,
Bijan J Borah,
Kristen Hassmiller Lich,
Michael Matney,
A Burak Ozbay,
Marcus Parton and
Paul J Limburg
PLOS ONE, 2020, vol. 15, issue 12, 1-23
Abstract:
Background: Real-world adherence to colorectal cancer (CRC) screening strategies is imperfect. The CRC-AIM microsimulation model was used to estimate the impact of imperfect adherence on the relative benefits and burdens of guideline-endorsed, stool-based screening strategies. Methods: Predicted outcomes of multi-target stool DNA (mt-sDNA), fecal immunochemical tests (FIT), and high-sensitivity guaiac-based fecal occult blood tests (HSgFOBT) were simulated for 40-year-olds free of diagnosed CRC. For robustness, imperfect adherence was incorporated in multiple ways and with extensive sensitivity analysis. Analysis 1 assumed adherence from 0%-100%, in 10% increments. Analysis 2 longitudinally applied real-world first-round differential adherence rates (base-case imperfect rates = 40% annual FIT vs 34% annual HSgFOBT vs 70% triennial mt-sDNA). Analysis 3 randomly assigned individuals to receive 1, 5, or 9 lifetime (9 = 100% adherence) mt-sDNA tests and 1, 5, or 9 to 26 (26 = 100% adherence) FIT tests. Outcomes are reported per 1000 individuals compared with no screening. Results: Each screening strategy decreased CRC incidence and mortality versus no screening. In individuals screened between ages 50–75 and adherence ranging from 10%a-100%, the life-years gained (LYG) for triennial mt-sDNA ranged from 133.1–300.0, for annual FIT from 96.3–318.1, and for annual HSgFOBT from 99.8–320.6. At base-case imperfect adherence rates, mt-sDNA resulted in 19.1% more LYG versus FIT, 25.4% more LYG versus HSgFOBT, and generally had preferable efficiency ratios while offering the most LYG. Completion of at least 21 FIT tests is needed to reach approximately the same LYG achieved with 9 mt-sDNA tests. Conclusions: Adherence assumptions affect the conclusions of CRC screening microsimulations that are used to inform CRC screening guidelines. LYG from FIT and HSgFOBT are more sensitive to changes in adherence assumptions than mt-sDNA because they require more tests be completed for equivalent benefit. At imperfect adherence rates, mt-sDNA provides more LYG than FIT or HSgFOBT at an acceptable tradeoff in screening burden.
Date: 2020
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0244431 (text/html)
https://journals.plos.org/plosone/article/file?id= ... 44431&type=printable (application/pdf)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:plo:pone00:0244431
DOI: 10.1371/journal.pone.0244431
Access Statistics for this article
More articles in PLOS ONE from Public Library of Science
Bibliographic data for series maintained by plosone ().