The relationship of tidal volume and driving pressure with mortality in hypoxic patients receiving mechanical ventilation
Robert A Raschke,
Brenda Stoffer,
Seth Assar,
Stephanie Fountain,
Kurt Olsen,
C William Heise,
Tyler Gallo,
Angela Padilla-Jones,
Richard Gerkin,
Sairam Parthasarathy and
Steven C Curry
PLOS ONE, 2021, vol. 16, issue 8, 1-15
Abstract:
Purpose: To determine whether tidal volume/predicted body weight (TV/PBW) or driving pressure (DP) are associated with mortality in a heterogeneous population of hypoxic mechanically ventilated patients. Methods: A retrospective cohort study involving 18 intensive care units included consecutive patients ≥18 years old, receiving mechanical ventilation for ≥3 days, with a PaO2/FiO2 ratio ≤300 mmHg, whether or not they met full criteria for ARDS. The main outcome was hospital mortality. Multiple logistic regression (MLR) incorporated TV/PBW, DP, and potential confounders including age, APACHE IVa® predicted hospital mortality, respiratory system compliance (CRS), and PaO2/FiO2. Predetermined strata of TV/PBW were compared using MLR. Results: Our cohort comprised 5,167 patients with mean age 61.9 years, APACHE IVa® score 79.3, PaO2/FiO2 166 mmHg and CRS 40.5 ml/cm H2O. Regression analysis revealed that patients receiving DP one standard deviation above the mean or higher (≥19 cmH20) had an adjusted odds ratio for mortality (ORmort) = 1.10 (95% CI: 1.06–1.13, p = 0.009). Regression analysis showed a U-shaped relationship between strata of TV/PBW and adjusted mortality. Using TV/PBW 4–6 ml/kg as the referent group, patients receiving >10 ml/kg had similar adjusted ORmort, but those receiving 6–7, 7–8 and 8–10 ml/kg had lower adjusted ORmort (95%CI) of 0.81 (0.65–1.00), 0.78 (0.63–0.97) and 0.80 0.67–1.01) respectively. The adjusted ORmort in patients receiving 4–6 ml/kg was 1.26 (95%CI: 1.04–1.52) compared to patients receiving 6–10 ml/kg. Conclusions: Driving pressures ≥19 cmH2O were associated with increased adjusted mortality. TV/PBW 4-6ml/kg were used in less than 15% of patients and associated with increased adjusted mortality compared to TV/PBW 6–10 ml/kg used in 82% of patients. Prospective clinical trials are needed to prove whether limiting DP or the use of TV/PBW 6–10 ml/kg versus 4–6 ml/kg benefits mortality.
Date: 2021
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0255812 (text/html)
https://journals.plos.org/plosone/article/file?id= ... 55812&type=printable (application/pdf)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:plo:pone00:0255812
DOI: 10.1371/journal.pone.0255812
Access Statistics for this article
More articles in PLOS ONE from Public Library of Science
Bibliographic data for series maintained by plosone ().