Field evaluation of the enhanced MM3-COPRO ELISA test for the diagnosis of Fasciola hepatica infection in sheep
Mercedes Mezo,
Marta González-Warleta,
José Antonio Castro-Hermida,
Victoria Martínez-Sernández and
Florencio M Ubeira
PLOS ONE, 2022, vol. 17, issue 3, 1-20
Abstract:
Fasciolosis is a severe zoonosis responsible for major economic losses in livestock. The enhanced MM3-COPRO test (eMM3-COPRO) and the commercial version BIO K 201 (Bio-X Diagnostics, Rochefort, Belgium) are widely used as immunodiagnostic tools for the specific detection of coproantigens released by Fasciola during the late prepatent and patent stages of infection. However, performance of the eMM3-COPRO has never been evaluated under field conditions. To address this gap, a large number of ovine faecal samples, collected in a region where fasciolosis is endemic (Galicia, NW Spain), were analyzed. Two groups of sheep flocks were selected according to the Fasciola infection status: ‘Fasciola-free’ and ‘Fasciola-infected’ flocks. ‘Fasciola-free’ flocks were seronegative flocks with no history of fasciolosis detected by either coproscopy or necropsy in the last 5 years. Faecal samples from these sheep were used to calculate a cut-off value for infection (OD = 0.021). The cut-off was calculated using a bootstrap resampling method that enables estimation of the sampling distribution of the statistical parameters without making assumptions about the underlying data distribution. ‘Fasciola-infected’ flocks were characterized by high seroprevalence, a history of fasciolosis and periodical treatment with flukicides. Samples from these flocks were used to estimate the diagnostic accuracy of the eMM3-COPRO relative to coproscopy, which although limited by poor sensitivity is the only reference test available for diagnosing fasciolosis in vivo. To overcome this limitation, all animals classified positive by eMM3-COPRO were treated with triclabendazole and then retested. The eMM3-COPRO displayed higher sensitivity than coproscopy, as it detected coproantigens in all samples with positive coproscopy and in 12% of samples with negative coproscopy. The test also proved highly specific as coproantigens disappeared after the treatment. The eMM3-COPRO was less time consuming than coproscopy, particularly when the procedure involved numerous samples, and showed promise as a tool for monitoring flukicide efficacy.
Date: 2022
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0265569 (text/html)
https://journals.plos.org/plosone/article/file?id= ... 65569&type=printable (application/pdf)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:plo:pone00:0265569
DOI: 10.1371/journal.pone.0265569
Access Statistics for this article
More articles in PLOS ONE from Public Library of Science
Bibliographic data for series maintained by plosone ().