EconPapers    
Economics at your fingertips  
 

Virtual monochromatic imaging with projection-based material decomposition algorithm for metal artifacts reduction in photon-counting detector computed tomography

Chia-Hao Chang, Hsiang-Ning Wu, Ching-Han Hsu and Hsin-Hon Lin

PLOS ONE, 2023, vol. 18, issue 3, 1-20

Abstract: Metal artifacts present a major challenge to computed tomography (CT) because they reduce the image quality in medical diagnosis and treatment. Several metal artifact reduction (MAR) methods have been proposed to address this issue in previous studies. This study aimed to synthesize a virtual monochromatic image for MAR in CT images using projection-based material decomposition (MD) algorithms. We developed a spectral micro-CT prototype system equipped with a photon-counting detector (PCD) and PCD-CT imaging simulator to assess the performances of different MAR methods. Two projection-based MD algorithms were implemented and evaluated for their MAR performances in CT images and compared with conventional sinogram inpainting MAR methods. Different parts of digital 4D-extended cardiac torso (XCAT) phantoms with metal implants were designed to simulate various real scenarios. A homemade metal artifact evaluation (MAE) phantom was used to evaluate the MAR performance in experiments. The simulated results of the XCAT phantom indicated that the projection-based virtual monochromatic CT (VMCT) images provided better image quality than the conventional MAR images without blurring the normal tissues at the position of the metal artifacts. Various quantitative indicators support this conclusion. Additionally, the experimental results of the MAE phantom reveal that projection-based VMCT images can avoid image distortion caused by metal artifacts, unlike conventional MAR methods. In regards to the projection-based VMCT images, the simulated and experimental results demonstrated that using the linear maximum likelihood estimators with an error correction look-up table algorithm yielded better MAR performance compared to that obtained using a polynomial algorithm. Furthermore, projection-based VMCT images can not only reduce metal artifacts effectively but also simultaneously prevents object blurring at the metal artifact position and image distortion of the metal implants. Hence, the CT image quality can be further improved to increase the abilities for both preoperative and postoperative assessment of metal implants.

Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0282900 (text/html)
https://journals.plos.org/plosone/article/file?id= ... 82900&type=printable (application/pdf)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:plo:pone00:0282900

DOI: 10.1371/journal.pone.0282900

Access Statistics for this article

More articles in PLOS ONE from Public Library of Science
Bibliographic data for series maintained by plosone ().

 
Page updated 2025-05-10
Handle: RePEc:plo:pone00:0282900