Abstract:
Interconnected transmission systems are increasingly spreading out in HV networks to enhance system efficiency, decrease reserve capacity, and improve service reliability. However, the protection of multi-terminal lines against Broken Conductor Fault (BCF) imposes significant difficulties in such networks as the conventional distance relays cannot detect BCF, as the BCF is not associated with a significant increase in current or reduction in voltage Traditionally, the earth fault relays in transmission lines may detect such fault; Nonetheless, it suffers from a long delay time. Moreover, many of the nearby earth fault relays detect the BCF causing unnecessary trips and badly affecting the system stability. In this article, a novel single-end scheme based on extracting transient features from current signals by discrete wavelet transform (DWT) is proposed for detecting BCFs in interconnected HV transmission systems. The suggested scheme unit (SSU) is capable of accurately detecting all types of BCFs and shunt high impedance faults (SHIFs). It also adaptively calculates the applied threshold values. The accurate selectivity in multi-terminal lines is achieved based on a fault directional element by analyzing transient power polarity. The SSU discriminates between internal/external faults effectively utilizing the time difference observed between the first spikes of aerial and ground modes in the current signals. Different fault scenarios have been simulated on the IEEE 9-Bus, 230 kV interconnected system. The achieved results confirm the effectiveness, robustness, and reliability of SSU in detecting correctly BCFs as well as the SHIFs within only 24.5 ms. The SSU has confirmed its capability to be implemented in interconnected systems without any requirement for communication or synchronization between the SSU installed in multi-terminal lines.
Date: 2024
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)
Downloads: (external link)
https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0296773 (text/html)
https://journals.plos.org/plosone/article/file?id= ... 96773&type=printable (application/pdf)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:plo:pone00:0296773
DOI: 10.1371/journal.pone.0296773
Access Statistics for this article
More articles in PLOS ONE from Public Library of Science
Bibliographic data for series maintained by plosone ().