A Machine-Learning Algorithm to Optimise Automated Adverse Drug Reaction Detection from Clinical Coding
Christopher McMaster (),
David Liew,
Claire Keith,
Parnaz Aminian and
Albert Frauman
Additional contact information
Christopher McMaster: Austin Health
David Liew: Austin Health
Claire Keith: Austin Health
Parnaz Aminian: Austin Health
Albert Frauman: Austin Health
Drug Safety, 2019, vol. 42, issue 6, No 4, 725 pages
Abstract:
Abstract Introduction Adverse drug reaction (ADR) detection in hospitals is heavily reliant on spontaneous reporting by clinical staff, with studies in the literature pointing to high rates of underreporting [1]. International Classification of Diseases, 10th Revision (ICD-10) codes have been used in epidemiological studies of ADRs and offer the potential for automated ADR detection systems. Objective The aim of this study was to develop an automated ADR detection system based on ICD-10 codes, using machine-learning algorithms to improve accuracy and efficiency. Methods For a 12-month period from December 2016 to November 2017, every inpatient episode receiving an ICD-10 code in the range Y40.0–Y59.9 (ADR code) was flagged for review as a potential ADR. Each flagged admission was assessed by an expert pharmacist and, if needed, reviewed at regular ADR committee meetings. For each report, a determination was made about ADR probability and severity. The dataset was randomly split into training and test sets. A machine-learning model using the random forest algorithm was developed on the training set to discriminate between true and false ADR reports. The model was then applied to the test set to assess accuracy using the area under the receiver operating characteristic (AUC). Results In the study period, 2917 Y40.0–Y59.9 codes were applied to admissions, resulting in 245 ADR reports after review. These 245 reports accounted for 44.5% of all ADR reporting in our hospital in the study period. A random forest model built on the training set was able to discriminate between true and false reports on the test set with an AUC of 0.803. Conclusions Automated ADR detection using ICD-10 coding significantly improved ADR detection in the study period, with improved discrimination between true and false reports by applying a machine-learning model.
Date: 2019
References: View complete reference list from CitEc
Citations: View citations in EconPapers (2)
Downloads: (external link)
http://link.springer.com/10.1007/s40264-018-00794-y Abstract (text/html)
Access to the full text of the articles in this series is restricted.
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:spr:drugsa:v:42:y:2019:i:6:d:10.1007_s40264-018-00794-y
Ordering information: This journal article can be ordered from
http://www.springer.com/adis/journal/40264
DOI: 10.1007/s40264-018-00794-y
Access Statistics for this article
Drug Safety is currently edited by Nitin Joshi
More articles in Drug Safety from Springer
Bibliographic data for series maintained by Sonal Shukla () and Springer Nature Abstracting and Indexing ().