EconPapers    
Economics at your fingertips  
 

Intravenous Medication Administration Safety with Smart Infusion Pumps in the Neonatal Intensive Care Unit: An Observational Study

Kumiko O. Schnock (), Sara E. Rostas, Catherine S. Yoon, Stuart Lipsitz, David W. Bates and Patricia C. Dykes
Additional contact information
Kumiko O. Schnock: Brigham and Women’s Hospital
Sara E. Rostas: Brigham and Women’s Hospital
Catherine S. Yoon: Brigham and Women’s Hospital
Stuart Lipsitz: Brigham and Women’s Hospital
David W. Bates: Brigham and Women’s Hospital
Patricia C. Dykes: Brigham and Women’s Hospital

Drug Safety, 2024, vol. 47, issue 1, No 3, 29-38

Abstract: Abstract Introduction Infants in the neonatal intensive care unit (NICU) are among the most vulnerable patient populations and medication errors are a significant source of risk and harm to neonates. Smart infusion pumps have been implemented to support the safe medication administration process; however, the effect of using smart infusion pumps on medication safety in the NICU is still unclear. Methods We conducted an observational study with a prospective point-prevalence approach to investigate intravenous (IV) medication administration errors in the NICU at one academic medical center in the USA. Observations were conducted in 48 days in a 3-month data collection period in 2019. Results We observed a total of 441 patients with 905 IV medication administrations during the data collection period. The total number of errors was 130 (14.4 per 100 administrations). Of these, the most frequent errors were selecting the wrong drug library entry (5.3 per 100 administrations), unauthorized medication (0.7 per 100 administrations), and wrong dose (0.6 per 100 administrations). Sixty-eight errors (7.5 per 100 administrations) were unlikely to cause harm despite reaching the patient (category C errors), while the rest did not reach the patient. Conclusion We identified the medication errors, which was unique to NICU populations, but no harm to the patients were identified. Most errors occurred due to a lack of compliance of using smart pump technology; therefore, potential exists to maximize safety related to medication administration practices in the NICU through hospital policy change and increasing adherence to appropriate use of smart pump technology.

Date: 2024
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
http://link.springer.com/10.1007/s40264-023-01365-6 Abstract (text/html)
Access to the full text of the articles in this series is restricted.

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:spr:drugsa:v:47:y:2024:i:1:d:10.1007_s40264-023-01365-6

Ordering information: This journal article can be ordered from
http://www.springer.com/adis/journal/40264

DOI: 10.1007/s40264-023-01365-6

Access Statistics for this article

Drug Safety is currently edited by Nitin Joshi

More articles in Drug Safety from Springer
Bibliographic data for series maintained by Sonal Shukla () and Springer Nature Abstracting and Indexing ().

 
Page updated 2025-04-12
Handle: RePEc:spr:drugsa:v:47:y:2024:i:1:d:10.1007_s40264-023-01365-6