Graphical Presentation of 50/60 Hz Magnetic Field Contours as an Engineering Tool for Minimizing ELF Fields
Josef Peker () and
Moshe Z. Netzer ()
Additional contact information
Josef Peker: EMC Engineering & Safety
Moshe Z. Netzer: EMC Engineering & Safety
Environment Systems and Decisions, 2005, vol. 25, issue 2, 201-208
Abstract:
Summary Since IARC classified ELF magnetic field as Possibly Carcinogenic to Human the fear from 50/60 Hz magnetic field exposure had been increased to the state of public “panic”. Subsequently, environment quality preservation organizations increased their pressure on their government to adopt the “precautionary principle” and to reduce the allowable ELF Magnetic Field exposure to much lower values than are recommended by ICNIRP-1998. As an example the present Environmental Ministry in Israel recommendation is to lower the ELF Field exposure to 10 mG averaged over 24 h. As a result of this stringent exposure guideline imposed by the government, electrical engineers who are involved in the deployment and installation of large and medium electrical utilities, such as overhead power lines, transformers, UPS systems, electrical public transportation, switching stations, etc., are much more aware to the need to employ special measures and methods for reducing the magnetic fields that might be emitted from such utilities. There are few computer codes that are capable of analyzing with great accuracy magnetic and electric fields surrounding single phase and three phase electrical utilities in a 3-D system. The best presentations of the analysis results are by equi-value contours depicting electric and magnetic fields. This graphical presentation is a powerful design tool that enables better deployment and installation design aided to reduce the magnetic field emissions from high-power electrical utilities. This paper describes the various types of graphical presentations available for ELF field contours, the dependent and independent variants and parameters, magnetic field animation for optimization of power line installation and routing, and finally an example that demonstrates the usefulness of the graphical presentation tools.
Keywords: extremely low magnetic (ELF) fields; electromagnetic compatibility (EMC); non-ionizing radiation; radiation hazards (RADHAZ); graphical presentations; permissible exposure limits (PEL); overhead high voltage (HV) power lines; high power electrical utilities (search for similar items in EconPapers)
Date: 2005
References: Add references at CitEc
Citations:
Downloads: (external link)
http://link.springer.com/10.1007/s10669-005-4284-8 Abstract (text/html)
Access to the full text of the articles in this series is restricted.
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:spr:envsyd:v:25:y:2005:i:2:d:10.1007_s10669-005-4284-8
Ordering information: This journal article can be ordered from
https://www.springer.com/journal/10669
DOI: 10.1007/s10669-005-4284-8
Access Statistics for this article
More articles in Environment Systems and Decisions from Springer
Bibliographic data for series maintained by Sonal Shukla () and Springer Nature Abstracting and Indexing ().