EconPapers    
Economics at your fingertips  
 

Detection and Assessment of Post Meter Leakages in Public Places Using Smart Water Metering

Ayse Muhammetoglu (), Yalçın Albayrak (), Mustafa Bolbol, Simge Enderoglu and Habib Muhammetoglu ()
Additional contact information
Ayse Muhammetoglu: Akdeniz University
Yalçın Albayrak: Akdeniz University
Mustafa Bolbol: Akdeniz University
Simge Enderoglu: Akdeniz University
Habib Muhammetoglu: Akdeniz University

Water Resources Management: An International Journal, Published for the European Water Resources Association (EWRA), 2020, vol. 34, issue 9, No 21, 2989-3002

Abstract: Abstract The current study aims to monitor, detect, and assess post meter water leakage in public areas including schools, graveyards, public toilets, parks, and universities. Twenty-two different public sites were selected within the current study and smart water meters of various sizes were installed in these pilot study sites (PSS). A real time monitoring program was conducted to measure the flow rates at these sites at 15-min time intervals for a period of six months in 2019. The flow occurrence was monitored every two minutes within a user predefined period of inspection, and hence a leak warning message is generated once a continuous flow was detected. Minimum water usage was observed during the minimum night flow (MNF) period from 00:00 to 05:00, therefore close monitoring of the MNF at shorter time intervals allows appropriate leakage detection with proper estimation of leakage volumes. High levels of post meter leakages were observed at all the PSS where the total leakage exceeded 58% of the total flow. On-site investigations and close monitoring revealed that significant water leakage volumes in these PSS are taking place due to poor management practices where deteriorated water connections in toilets and water taps are the main contributing factors to the water leakages in most of these PSS. The results indicated that such huge leakage can be resolved at a low cost. A frequency analysis of the monitored flow rates was found efficient in analyzing the suitability of the installed meter sizes.

Keywords: Meter size; Monitoring; Post meter leakage; Public places; Smart metering; Unbilled authorized consumption (search for similar items in EconPapers)
Date: 2020
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
http://link.springer.com/10.1007/s11269-020-02598-1 Abstract (text/html)
Access to the full text of the articles in this series is restricted.

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:spr:waterr:v:34:y:2020:i:9:d:10.1007_s11269-020-02598-1

Ordering information: This journal article can be ordered from
http://www.springer.com/economics/journal/11269

DOI: 10.1007/s11269-020-02598-1

Access Statistics for this article

Water Resources Management: An International Journal, Published for the European Water Resources Association (EWRA) is currently edited by G. Tsakiris

More articles in Water Resources Management: An International Journal, Published for the European Water Resources Association (EWRA) from Springer, European Water Resources Association (EWRA)
Bibliographic data for series maintained by Sonal Shukla () and Springer Nature Abstracting and Indexing ().

 
Page updated 2025-03-20
Handle: RePEc:spr:waterr:v:34:y:2020:i:9:d:10.1007_s11269-020-02598-1