Analyzing and modeling thermal complaints in a commercial building in France
Kocaman Ezgi,
Kuru Merve and
Çalış Gülben ()
Additional contact information
Kocaman Ezgi: Ege University, Department of Civil Engineering, Bornova 35040 İzmir, Turkey
Kuru Merve: Ege University, Department of Civil Engineering, Bornova 35040 İzmir, Turkey
Çalış Gülben: Ege University, Department of Civil Engineering, Bornova 35040 İzmir, Turkey
Organization, Technology and Management in Construction, 2021, vol. 13, issue 1, 2416-2425
Abstract:
Buildings are interactive environments in which their operations and occupants are linked. Although buildings are operated according to the standards, occupant complaints may arise when there is a mismatch between indoor environmental conditions and actual user needs. Therefore, the accuracy of thermal comfort prediction models suggested by the standards and alternative prediction models need to be investigated. This study aims at assessing the performance of the predicted mean vote (PMV) model suggested by the ISO 7730 Standard to detect occupant thermal dissatisfaction. In addition, a multivariate logistic regression model was developed to predict thermal complaints with respect to “too warm” and “too cold.” This case study was conducted in a commercial building located in Paris, France, between January 2017 and May 2018. Indoor environmental conditions were monitored via sensors and an online tool was used to collect occupant thermal complaints. A total of 53 thermal complaints were analyzed. The results showed that all the operative temperature measurements in both the heating and cooling seasons were within the thresholds suggested by the standards. The PMV method suggested that only 4% of the occupants were dissatisfied with the indoor environment whereas the actual dissatisfaction ratio was 100% under these indoor environmental conditions. In addition, the multivariate logistic regression model showed that operative temperature and season have a significant effect on thermal complaints. Furthermore, the accuracy of the developed model was 90.6%.
Keywords: thermal dissatisfaction; thermal complaint; PMV–PPD model; logistic regression (search for similar items in EconPapers)
Date: 2021
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://doi.org/10.2478/otmcj-2020-0017 (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:vrs:otamic:v:13:y:2021:i:1:p:2416-2425:n:6
DOI: 10.2478/otmcj-2020-0017
Access Statistics for this article
Organization, Technology and Management in Construction is currently edited by Mladen Radujković
More articles in Organization, Technology and Management in Construction from Sciendo
Bibliographic data for series maintained by Peter Golla ().