Heat of Combustion as the Key Fire Characteristics of Electrical Cables
Martinka Jozef (),
Rantuch Peter (),
Hladová Martina (),
Sulová Janka (),
Nečas Aleš (),
Benko Denis () and
Balog Karol ()
Additional contact information
Martinka Jozef: Slovak University of Technology in Bratislava, Faculty of Materials Science and Technology in Trnava, Institute of Integrated Safety, Ulica Jána Bottu 2781/25, 917 24Trnava, Slovakia
Rantuch Peter: Slovak University of Technology in Bratislava, Faculty of Materials Science and Technology in Trnava, Institute of Integrated Safety, Ulica Jána Bottu 2781/25, 917 24Trnava, Slovakia
Hladová Martina: Slovak University of Technology in Bratislava, Faculty of Materials Science and Technology in Trnava, Institute of Integrated Safety, Ulica Jána Bottu 2781/25, 917 24Trnava, Slovakia
Sulová Janka: VUKI, A.S., Rybničná 38, 831 07Bratislava, Slovakia
Nečas Aleš: Slovak University of Technology in Bratislava, Faculty of Materials Science and Technology in Trnava, Institute of Integrated Safety, Ulica Jána Bottu 2781/25, 917 24Trnava, Slovakia
Benko Denis: Slovak University of Technology in Bratislava, Faculty of Materials Science and Technology in Trnava, Institute of Integrated Safety, Ulica Jána Bottu 2781/25, 917 24Trnava, Slovakia
Balog Karol: Slovak University of Technology in Bratislava, Faculty of Materials Science and Technology in Trnava, Institute of Integrated Safety, Ulica Jána Bottu 2781/25, 917 24Trnava, Slovakia
Research Papers Faculty of Materials Science and Technology Slovak University of Technology, 2019, vol. 27, issue 44, 29-39
Abstract:
This scientific study deals with investigation of the heat of combustion and effective heat of combustion of selected electrical cables. Two different electrical cables for rated voltage of 0.6/1 kV were investigated. Both cables were power three-core with cross-section area of each core of 1.5 mm2. The cores of both cables were made of a bar cooper wire. Insulations of conductors of both cables were made of silane cross-linked polyethylene without any inorganic filler, while the bedding and outer sheath were made of polyethylene-based copolymer (the beddings were filled with two fillers - aluminium hydroxide and calcium carbonate, while the outer sheath were filled only with aluminium hydroxide). Reaction to fire class of both cables was B2ca, s1, d0, a1. The main difference in the investigated cables was that the core of one of them was wrapped in a glass mica tape (this cable showed circuit integrity maintenance under fire conditions during 180 minutes). The heat of combustion and effective heat of combustion were determined by the oxygen bomb calorimeter according to the ISO 1716:2018 standard. The highest effective heat of combustion showed the insulation of wires (for both cables 42.47 ± 0.03 MJ/kg), lower value showed outer sheath (interval form13.61 to 15.26 MJ/kg) and the lowest value was determined for bedding (interval from 4.69 to 6.39 MJ/kg). The effective heath of combustion per unit of length of both investigated cables lies in the interval from 1.37 to 1.38 MJ/m. Therefore, there is no significant difference in effective heats of combustion of the electrical cables investigated.
Keywords: Electrical cable; effective heat of combustion; fire load; fire risk; oxygen bomb calorimeter (search for similar items in EconPapers)
Date: 2019
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
https://doi.org/10.2478/rput-2019-0003 (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:vrs:repfms:v:27:y:2019:i:44:p:29-39:n:3
DOI: 10.2478/rput-2019-0003
Access Statistics for this article
Research Papers Faculty of Materials Science and Technology Slovak University of Technology is currently edited by Kvetoslava Rešetová
More articles in Research Papers Faculty of Materials Science and Technology Slovak University of Technology from Sciendo
Bibliographic data for series maintained by Peter Golla ().