Impact of Selected Electrical Cables Slope on Flame Out Time and Flame Spread

Nečas Aleš (), Martinka Jozef (), Wachter Igor (), Štefko Tomáš (), Hladová Martina (), Benko Denis (), Balog Karol () and Ševčík Libor ()
Additional contact information
Nečas Aleš: Slovak University of Technology in Bratislava, Faculty of Materials Science and Technology in Trnava, Institute of Integrated Safety, Ulica Jána Bottu 2781/25, 917 24Trnava, Slovakia
Martinka Jozef: Slovak University of Technology in Bratislava, Faculty of Materials Science and Technology in Trnava, Institute of Integrated Safety, Ulica Jána Bottu 2781/25, 917 24Trnava, Slovakia
Wachter Igor: Slovak University of Technology in Bratislava, Faculty of Materials Science and Technology in Trnava, Institute of Integrated Safety, Ulica Jána Bottu 2781/25, 917 24Trnava, Slovakia
Štefko Tomáš: Slovak University of Technology in Bratislava, Faculty of Materials Science and Technology in Trnava, Institute of Integrated Safety, Ulica Jána Bottu 2781/25, 917 24Trnava, Slovakia
Hladová Martina: Slovak University of Technology in Bratislava, Faculty of Materials Science and Technology in Trnava, Institute of Integrated Safety, Ulica Jána Bottu 2781/25, 917 24Trnava, Slovakia
Benko Denis: Slovak University of Technology in Bratislava, Faculty of Materials Science and Technology in Trnava, Institute of Integrated Safety, Ulica Jána Bottu 2781/25, 917 24Trnava, Slovakia
Balog Karol: Slovak University of Technology in Bratislava, Faculty of Materials Science and Technology in Trnava, Institute of Integrated Safety, Ulica Jána Bottu 2781/25, 917 24Trnava, Slovakia
Ševčík Libor: Ministry of Interior of the Czech Republic, Technical Institute of Fire Protection, Písková 42, 143 00, Prague 4, Czech Republic

Research Papers Faculty of Materials Science and Technology Slovak University of Technology, 2019, vol. 27, issue 44, 41-47

Abstract: The aim of the research described in this paper was to study the impact of the electrical cables slope on the flame out time and the flame spread rate. Measured cables were thermally loaded by methanol flame (diameter of the container was 106 mm) at seven different slopes with respect to the horizontal plane (the slopes were 0° – horizontal orientation, 15°, 30°, 45°, 60°, 75° and 90° - vertical orientation). The first tested electrical cable was a copper three-core power one resistant to the flame spread with circuit integrity of the cable system during 30 minutes under fire (cross-section of each core was 1.5 mm2). The second tested electrical cable was a copper two-core signal one resistant to the flame spread with circuit integrity of the cable system during 30 minutes under fire (cross-section of each core was 0.5 mm2). The first electrical cable did not show reaction to fire class. The reaction to fire class of the second tested cable was B2ca, s1, d1, a1. The obtained results proved that slope had virtually no impact on the flame out time and the flame spread over the tested cable surface (tested cables of all slopes stopped burning after 1 to 5 seconds after methanol flame burned out). Likewise, the flame spread was only negligibly beyond the border of flame action for each cable slope.

Keywords: Electrical cable; ignition; flame spread; flame out time; safety (search for similar items in EconPapers)
Date: 2019
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
https://doi.org/10.2478/rput-2019-0004 (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:vrs:repfms:v:27:y:2019:i:44:p:41-47:n:4

DOI: 10.2478/rput-2019-0004

Access Statistics for this article

Research Papers Faculty of Materials Science and Technology Slovak University of Technology is currently edited by Kvetoslava Rešetová

More articles in Research Papers Faculty of Materials Science and Technology Slovak University of Technology from Sciendo
Bibliographic data for series maintained by Peter Golla ().

 
Page updated 2025-03-20
Handle: RePEc:vrs:repfms:v:27:y:2019:i:44:p:41-47:n:4