EconPapers    
Economics at your fingertips  
 

Agreement of infrared temporal artery thermometry with other thermometry methods in adults: systematic review

Panagiotis Kiekkas, Nikolaos Stefanopoulos, Nick Bakalis, Antonios Kefaliakos and Menelaos Karanikolas

Journal of Clinical Nursing, 2016, vol. 25, issue 7-8, 894-905

Abstract: Aims and objectives To critically review and synthesise the evidence on the agreement of temporal artery thermometry with invasive and noninvasive thermometry methods in hospitalised adults. Background Noninvasive thermometry methods aim at combining patient comfort and ease of use with satisfactory accuracy of temperature measurements. Infrared temporal artery thermometry is based on the detection of heat radiated from this artery in the forehead and temporal region. Design Systematic literature review. Methods A literature search was conducted in Pubmed, CINAHL, Cochrane Library, Web of Science and Embase. Data were extracted from twenty method‐comparison studies published between 2002–2015. Methodological quality of selected studies was evaluated. Results Temperature measurements of temporal artery were compared with pulmonary artery, urinary bladder, oesophageal or nasopharyngeal ones in eight studies for the whole temperature range. Accuracy and precision of temporal artery thermometry exceeded recommended levels of 0·3°C in three and six studies respectively. Likewise, in nine studies that compared temporal artery temperature measurements with oral and ear‐based ones, satisfactory agreement and variability was reported in five and none of them respectively. With regard to fever and hypothermia, although specificity of temporal artery thermometers for detecting these disorders was satisfactory, their sensitivity was low. Conclusions Existing evidence does not support that temporal artery thermometry can replace common invasive and noninvasive thermometry methods in adult patients. Relevance to clinical practice Health care professionals are recommended to avoid the use of infrared temporal artery temporal artery thermometry in adults, or be cautious about the accuracy and precision of its readings, until improved devices are developed.

Date: 2016
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
https://doi.org/10.1111/jocn.13117

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:wly:jocnur:v:25:y:2016:i:7-8:p:894-905

Access Statistics for this article

More articles in Journal of Clinical Nursing from John Wiley & Sons
Bibliographic data for series maintained by Wiley Content Delivery ().

 
Page updated 2025-03-20
Handle: RePEc:wly:jocnur:v:25:y:2016:i:7-8:p:894-905