Abstract: Aims and objectives To investigate whether the type of dressing used (occlusive vs. semi‐occlusive) impacts on exit‐site infection. Background The exit‐site infections are a major predisposing factor for peritoneal dialysis‐related peritonitis, the main cause of technique failure and an important cause of mortality. The care taken in exit‐site dressing is considered an important procedure for the prevention of trauma and contamination of this area. Nevertheless, to our knowledge, no study has yet analysed the impact of different dressing types on early exit‐site infection (up to two months after catheter insertion). Design A prospective observational study involving the BRAZPD II (Brazilian Peritoneal Dialysis Multicenter Study) cohort. Methods All incident patients with data available for dressing type applied following peritoneal dialysis catheter insertion were included in the study. A multilevel logistic regression model was used to compare the log‐odds of exit‐site infections between groups. Results A total of 2460 incident patients were included. Occlusive and semi‐occlusive dressings were applied in 82·6% (n = 2031) and 17·4% (n = 427) of patients, respectively. Exit‐site infection incidence was not affected by the type of dressing used, with a logit for occlusive dressing of 2·15 (95% CI 0·81–5·70). The combined outcome of exit‐site infection and tunnel infection also showed no significance between the groups (logit 1·46, 95% CI 0·72–2·97). Conclusion Our results indicate that the type of exit‐site dressing used during the healing phase following peritoneal dialysis catheter insertion has no impact on early exit‐site infection rates. Relevance to clinical practice Provides evidence to support the similarity between occlusive and semi‐occlusive dressing regarding infection rates in exit site of peritoneal dialysis catheter, therefore allowing the choice to be made accordingly to routine or availability.

Date: 2017
References: View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
https://doi.org/10.1111/jocn.13738

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:wly:jocnur:v:26:y:2017:i:21-22:p:3658-3663

Access Statistics for this article

More articles in Journal of Clinical Nursing from John Wiley & Sons
Bibliographic data for series maintained by Wiley Content Delivery ().

 
Page updated 2025-03-20
Handle: RePEc:wly:jocnur:v:26:y:2017:i:21-22:p:3658-3663