An experimental investigation on the integration of two-stage dehumidification and regenerative evaporative cooling
D. La,
Y.J. Dai,
Y. Li,
Z.Y. Tang,
T.S. Ge and
R.Z. Wang
Applied Energy, 2013, vol. 102, issue C, 1218-1228
Abstract:
A novel chiller with open-cycle rotary desiccant cooling has been investigated experimentally. The technologies of two-stage dehumidification and regenerative evaporative cooling have been integrated together in this chiller. The objective of this study is to extend the ability for handling sensible heat of the rotary desiccant cooling system. Based on the experimental results, it is found that the novel chiller is a good choice for space cooling using low-grade heat source. The temperature of the supply chilled water from this unit is around 15–20°C. The thermal coefficient of performance is about 0.3–0.6 in terms of the chilled water production. Furthermore, the rotary desiccant cooling system, which produces both dry air and chilled water, is proved to be superior to the conventional rotary desiccant cooling system in handling the sensible heat. Especially, under humid and high humid conditions, the effective cooling capacity of the novel system is still at a favorable level. The specific thermal coefficient of performance of the novel rotary desiccant cooling system is around 0.8–0.9 considering the production of both chilled water and dry air.
Keywords: Desiccant cooling; Chiller; Two-stage dehumidification; Regenerative evaporative cooling; Air conditioning (search for similar items in EconPapers)
Date: 2013
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (15)
Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0306261912004989
Full text for ScienceDirect subscribers only
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:eee:appene:v:102:y:2013:i:c:p:1218-1228
Ordering information: This journal article can be ordered from
http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/bibliographic
http://www.elsevier. ... 405891/bibliographic
DOI: 10.1016/j.apenergy.2012.06.053
Access Statistics for this article
Applied Energy is currently edited by J. Yan
More articles in Applied Energy from Elsevier
Bibliographic data for series maintained by Catherine Liu ().