Annual evaluation of energy, environmental and economic performances of a membrane liquid desiccant air conditioning system with/without ERV
Ahmed H. Abdel-Salam and
Carey J. Simonson
Applied Energy, 2014, vol. 116, issue C, 134-148
Abstract:
In this study, a membrane liquid desiccant air conditioning (M-LDAC) system is modeled using the TRNSYS building energy simulation software. Liquid-to-air membrane energy exchangers (LAMEEs) are used as a dehumidifier and regenerator in the proposed M-LDAC system to eliminate the carryover of desiccant droplets in supply and exhaust air streams, which may occur when direct-contact conditioners are used. A sensitivity study on the sensible, latent and total effectivenesses of the LAMEEs is performed under 36 operating and design conditions. The technical, environmental and economic performances of the proposed M-LDAC system are evaluated, and compared to those of a conventional air conditioning (CAC) system. The influences of installing an energy recovery ventilator (ERV) under balanced and unbalanced airflow rates conditions are investigated. Results show that the annual primary energy consumption and the life cycle cost (LCC) of the proposed M-LDAC system are 19% and 12% lower than that of the CAC system, and they reach 32% and 21% when an ERV, which operates under balanced airflow rates, is installed in the M-LDAC system.
Keywords: Annual performance analysis; Effectiveness; Environmental emissions; ERV; Life cycle cost; Membrane liquid desiccant air conditioning (search for similar items in EconPapers)
Date: 2014
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (28)
Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0306261913009537
Full text for ScienceDirect subscribers only
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:eee:appene:v:116:y:2014:i:c:p:134-148
Ordering information: This journal article can be ordered from
http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/bibliographic
http://www.elsevier. ... 405891/bibliographic
DOI: 10.1016/j.apenergy.2013.11.047