Operating characteristics and performance improvements of a 500W traveling-wave thermoacoustic electric generator
Kai Wang,
Daming Sun,
Jie Zhang,
Ya Xu,
Jiang Zou,
Ke Wu,
Limin Qiu and
Zhiyi Huang
Applied Energy, 2015, vol. 160, issue C, 853-862
Abstract:
Traveling-wave thermoacoustic electric generator has drawn increasing attention due to its great prospect in energy conversion. In this work, a traveling-wave thermoacoustic electric generator capable of generating about 500W electric power is studied numerically and experimentally. The performances and the operating characteristics of the system under different working conditions are tested and analyzed. The maximum electric powers can be obtained with electric load resistance around 100–120Ω, and the highest thermal-to-electric efficiencies can be achieved at much larger load resistances. The efficiency at low load resistance is relatively small due to the large pressure amplitudes inside the thermoacoustic system, which increases the dissipations. The variation trends of the electric power and the thermal-to-electric efficiency with the load resistance intrinsically result from the changes of the corresponding acoustic impedance of the linear alternators, which determines the output performance of the thermoacoustic engine meanwhile. The distributions of the acoustic power losses are then calculated and firstly illustrated quantitatively. It is shown that the resonator causes most of the acoustic power losses, and the losses in hot heat exchanger, thermal buffer tube, and feedback tube are also significant. The output performance of the system can be improved by increasing the heating temperature and the mean pressure. A maximum electric power of 473.6W and a highest thermal-to-electric efficiency of 14.5% are achieved experimentally when the mean pressure is 2.48MPa and the heating temperature is 650°C. A pair of linear alternators with a larger swept volume and appropriate acoustic impedances is finally designed to couple with the thermoacoustic torus directly. Numerical results show that the maximum electric power can be increased to 718W and 1005W when the mean pressures are kept at 2.48MPa and 3.20MPa, corresponding to the improvements of 42.6% and 29.4% compared with those of the original system.
Keywords: Thermoacoustic; Electric generation; Linear alternator; Acoustic power (search for similar items in EconPapers)
Date: 2015
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (16)
Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0306261915003876
Full text for ScienceDirect subscribers only
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:eee:appene:v:160:y:2015:i:c:p:853-862
Ordering information: This journal article can be ordered from
http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/bibliographic
http://www.elsevier. ... 405891/bibliographic
DOI: 10.1016/j.apenergy.2015.03.085
Access Statistics for this article
Applied Energy is currently edited by J. Yan
More articles in Applied Energy from Elsevier
Bibliographic data for series maintained by Catherine Liu ().