Measured thermal performance of a combined suspended particle switchable device evacuated glazing
Aritra Ghosh,
Brian Norton and
Aidan Duffy
Applied Energy, 2016, vol. 169, issue C, 469-480
Abstract:
A switchable suspended particle device (SPD) evacuated (vacuum) glazing has low inherent heat loss and can control solar heat gain by changing its transparency. The thermal performance of combined SPD–vacuum glazing has been investigated using a test cell. In this work two different combination of SPD–vacuum glazing was evaluated. In the first combination, SPD glazing was facing the outside ambient environment and vacuum glazing was facing the indoor test cell environment (SPD–vacuum). In the second combination, SPD glazing was facing the indoor test cell environment and vacuum glazing was facing the outdoor ambient environment (Vacuum–SPD). Variation of the SPD glazing position in a combined SPD–vacuum glazing had little impact on either the internal test cell temperature or the glazing surface temperature. This combined glazing system achieved a dynamic transmission range from 2% (opaque state) to 38% (transparent state). Low overall heat transfer coefficients between 1.00W/m2K to 1.16W/m2K were found for this combined glazing. Dynamic solar heat gain coefficient was possible using this glazing, which varied from 0.045 to 0.27. This type of combined glazing system is suitable for summer and winter both conditions.
Keywords: SPD; Vacuum; Electrochromic; Smart window; Heat transfer coefficients; Test cell (search for similar items in EconPapers)
Date: 2016
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (17)
Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0306261916301544
Full text for ScienceDirect subscribers only
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:eee:appene:v:169:y:2016:i:c:p:469-480
Ordering information: This journal article can be ordered from
http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/bibliographic
http://www.elsevier. ... 405891/bibliographic
DOI: 10.1016/j.apenergy.2016.02.031
Access Statistics for this article
Applied Energy is currently edited by J. Yan
More articles in Applied Energy from Elsevier
Bibliographic data for series maintained by Catherine Liu ().