EconPapers    
Economics at your fingertips  
 

Integrating district cooling systems in Locally Integrated Energy Sectors through Total Site Heat Integration

Peng Yen Liew, Timothy Gordon Walmsley, Sharifah Rafidah Wan Alwi, Zainuddin Abdul Manan, Jiří Jaromír Klemeš and Petar Sabev Varbanov

Applied Energy, 2016, vol. 184, issue C, 1350-1363

Abstract: Between 20% and 50% of world energy consumption is lost as waste heat through energy conversion and transportation in manufacturing processes. Within industrial clusters and Locally Integrated Energy Systems (LIES), waste heat recovery for the purpose of heating and power generation has been well established via schemes such as process streams Heat Integration, cogeneration system, district heating integration, boiler feed water preheating and Organic Rankine Cycle. Waste heat can also be used to generate cooling energy via technologies such as the absorption chiller. During the summer season and in tropical countries, space cooling in buildings typically consumes up to 50% of the total energy consumption. Further recovery of waste heat to generate cooling can result in huge energy savings and emission reduction. This paper presents a new Total Site Energy Integration concept that integrates not only heat and power, but also cooling. The waste heat technology considered for cooling generation are Absorption Chiller (AC) and Electric Compression Chiller (EC). As there is actually an economic trade-off between amounts of chilled water generated, cooling water and power consumed, the new framework has been proposed to guide users in selecting the most economical waste heat-to-cooling technology for Industrial Clusters and LIES. For the presented case study, the lowest-cost solution used a waste-heat driven AC supplying 4.0MW of Chilled Water (ChW) and a supplementary EC supplying the remaining 1.0MW. The electricity demand of the integrated system is loaded by 1.3MWe through this ChW generation system configuration, while the cooling tower load is increased by 3.3MW. The ChW is expected to be generated at USD 115.10/kWy compared to USD 270.9/kWy for generating ChW by a conventional EC system without waste heat recovery.

Keywords: Total Site Heat Integration; Process Integration; District cooling system; Chilled water network; Waste heat (search for similar items in EconPapers)
Date: 2016
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (25)

Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0306261916306754
Full text for ScienceDirect subscribers only

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:eee:appene:v:184:y:2016:i:c:p:1350-1363

Ordering information: This journal article can be ordered from
http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/bibliographic
http://www.elsevier. ... 405891/bibliographic

DOI: 10.1016/j.apenergy.2016.05.078

Access Statistics for this article

Applied Energy is currently edited by J. Yan

More articles in Applied Energy from Elsevier
Bibliographic data for series maintained by Catherine Liu ().

 
Page updated 2025-03-19
Handle: RePEc:eee:appene:v:184:y:2016:i:c:p:1350-1363