An analysis on the energy consumption of circulating pumps of residential swimming pools for peak load management

Chunhe Song, Wei Jing, Peng Zeng and Catherine Rosenberg

Applied Energy, 2017, vol. 195, issue C, 12 pages

Abstract: Based on an extensive dataset containing aggregated hourly energy consumption readings of residents during March 2011 and October 2012 in South Ontario, Canada, this paper estimates the energy consumption of circulating pumps of residential swimming pools (CPRSP) non-intrusively, and quantifies the impact of CPRSP on the power system. The main challenges are that, first, widely used non-intrusive appliance load monitoring (NIALM) methods are not applicable to this work, due to the low sampling rate and the lack of the energy consumption pattern of CPRSP; second, temperature-based building energy disaggregation methods are not suitable for this work, as they highly depend on the accurate base load estimation and predefined parameters. To overcome these issues, in this paper, first it is found that, during the pool season, for homes with and without swimming pools, the ratio between their base loads is approximately equal to the ratio between their temperature-dependent energy consumptions, then a novel weighted difference change-point (WDCP) model has been proposed. The advantages of the WDCP model are that, on one hand, it doesn’t depend on the base load estimation and predefined parameters; on the other hand, it has no requirement on the data sampling rate and the prior information of energy consumption patterns of CPRSP. Based on the WDCP model it is shown that, the average hourly energy consumption of CPRSP is 0.7425kW, and the minimum and the maximum hourly energy consumptions are 0.5274kW at 9:00 and 0.9612kW at 17:00, respectively. At the peak hour 19:00, July 21, 2011, CPRSP contributes 20.36% energy consumption of homes with swimming pools, as well as 8.48% peak load of all neighborhoods. As a result, the peak load could be reduced by 8.48% if all CPRSP are stopped during the peak hour.

Keywords: Energy disaggregation; Residential swimming pool; Circulating pump; Peak load (search for similar items in EconPapers)
Date: 2017
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (6)

Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0306261917302416
Full text for ScienceDirect subscribers only

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:eee:appene:v:195:y:2017:i:c:p:1-12

Ordering information: This journal article can be ordered from
http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/bibliographic
http://www.elsevier. ... 405891/bibliographic

DOI: 10.1016/j.apenergy.2017.03.023

Access Statistics for this article

Applied Energy is currently edited by J. Yan

More articles in Applied Energy from Elsevier
Bibliographic data for series maintained by Catherine Liu ().

 
Page updated 2025-03-19
Handle: RePEc:eee:appene:v:195:y:2017:i:c:p:1-12