Study of operation strategies for integrating ice-storage district cooling systems into power dispatch for large-scale hydropower utilization
Ling Hao,
Mingshan Wei,
Fei Xu,
Xiaochen Yang,
Jia Meng,
Panpan Song and
Yong Min
Applied Energy, 2020, vol. 261, issue C, No S0306261919321658
Abstract:
Hydropower curtailment for the run-of-over stations has become serious in Southwest China. The ice-storage district cooling system is believed as an effective approach to provide flexibility for hydropower utilization. However, the existing ice-storage operation strategies in demand-side management cause that the ice storage cannot be adjusted in real-time to match the surplus hydropower, which brings difficulties for large-scale hydropower utilization. Therefore, this paper proposed the integration of ice-storage district cooling systems into power dispatch based on smart grid. Two operation strategies were developed for the integration to achieve power supply-side management of ice-storage district cooling system. One is the new ice-storage power-linked operation strategy, which was proposed to determine the ice storing/ melting capacity in the power dispatch. The other one is the cooling pipelines dynamic-characteristics-considered operation strategy, which was applied in the power dispatch. The dynamic characteristics were calculated based on a linear model to be compatible with the linear constraints in power dispatch models. Finally, effects of two strategies were studied by taking scenes in Chongqing as the example. Results showed that the application of the first strategy only reduces the hydropower curtailment frequency, while application of the second strategy reduces both the curtailment frequency and amount. Furthermore, the simultaneous applications of the above two strategies enhance hydropower consumption by 7.5% (200 million kW·h) and reduce carbon emission by 7.4% (34,000 tons) every year. In addition, there exists an optimal total ice-storage capacity per day, i.e. 8600 MW·h, under which the system’s performance reaches the highest value.
Keywords: Hydropower utilization; Ice-storage district cooling system; Power dispatch; Smart grid; Power-linked strategy; Cooling pipelines operation strategy (search for similar items in EconPapers)
Date: 2020
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (7)
Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0306261919321658
Full text for ScienceDirect subscribers only
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:eee:appene:v:261:y:2020:i:c:s0306261919321658
Ordering information: This journal article can be ordered from
http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/bibliographic
http://www.elsevier. ... 405891/bibliographic
DOI: 10.1016/j.apenergy.2019.114477
Access Statistics for this article
Applied Energy is currently edited by J. Yan
More articles in Applied Energy from Elsevier
Bibliographic data for series maintained by Catherine Liu ().