EconPapers    
Economics at your fingertips  
 

Enhancing risk control ability of distribution network for improved renewable energy integration through flexible DC interconnection

Hao Xiao, Wei Pei, Wei Deng, Tengfei Ma, Shizhong Zhang and Li Kong

Applied Energy, 2021, vol. 284, issue C, No S030626192031761X

Abstract: The increased penetration of distributed renewable energy into modern distribution networks has resulted in a significant rise in the system operational risk. However, the risk control ability of traditional open-loop AC distribution networks is greatly limited due to the inherent restriction of the network structure, which hinders the integration of larger-scale renewable energy into the power grid. To address this issue, this paper developed an effective risk assessment model and risk averse method for fully utilizing flexible DC interconnections to enhance the risk control ability and to improve the penetration of renewable energy in distribution networks. Moreover, aiming at the complex coupling risk characteristics between the AC and DC system that are imposed by the DC interconnection and considering the inefficiency of traditional Monte Carlo sampling risk assessment methods, an effective point-estimation-based risk assessment method is proposed that conducts a limited number of sequential AC/DC power flow calculations with estimation points constructed from random input variables, thereby the operational risk of the system is effectively realized. On this basis, a risk-averse multi-objective optimization model is further established for minimizing both the operational risk and the expected network power loss, and an improved kriging-model-assisted multi-object gray wolf algorithm is proposed for quickly supporting the model solution. Finally, a fuzzy clustering method is presented for effectively identifying the optimal Pareto solution. A case study is conducted on an AC/DC hybrid system with three AC networks and one DC network. The results demonstrate that the proposed method can substantially improve the risk assessment efficiency compared with the traditional Monte Carlo method. In addition, the risk-averse optimization method can effectively reduce the system risk and improve the operational reliability as well as the penetration of renewable energy.

Keywords: AC-DC hybrid distribution network; Risk assessment; Renewable energy integration; Multi-objective optimization; Fuzzy clustering (search for similar items in EconPapers)
Date: 2021
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (8)

Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S030626192031761X
Full text for ScienceDirect subscribers only

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:eee:appene:v:284:y:2021:i:c:s030626192031761x

Ordering information: This journal article can be ordered from
http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/bibliographic
http://www.elsevier. ... 405891/bibliographic

DOI: 10.1016/j.apenergy.2020.116387

Access Statistics for this article

Applied Energy is currently edited by J. Yan

More articles in Applied Energy from Elsevier
Bibliographic data for series maintained by Catherine Liu ().

 
Page updated 2025-03-19
Handle: RePEc:eee:appene:v:284:y:2021:i:c:s030626192031761x