EconPapers    
Economics at your fingertips  
 

Energy cascade connection of a low-temperature district heating network to the return line of a high-temperature district heating network

Anna Volkova, Igor Krupenski, Aleksandr Ledvanov, Aleksandr Hlebnikov, Kertu Lepiksaar, Eduard Latõšov and Vladislav Mašatin

Energy, 2020, vol. 198, issue C

Abstract: Heat supply from sustainable low-temperature district heating networks (LTDHN) can be considered as one of the most favourable heat supply option for urban buildings. If buildings are located in an area where heat is supplied by a well-established high-temperature district heating network (HTDHN) then it can be a problem to switch to low-temperature district heating. It can be possible in the case of a new planed buildings or buildings which will be fully renovated. There is an option to design them for LTDHN parameters and utilise the heat from the network return line. If those buildings are located closely, than it can be possible to establish a LTDHN branch connected to existing HTDHN. The goal of the study is to evaluate the technical and economic feasibility of integrating the energy cascade LTDHN into the existing large-scale HTDHN. Additional energy is necessary to raise the HTDHN return heating media temperature to the acceptable low-temperature district heating level because the return water temperature of HTDHN return line is, on average, 40–50 °C depending on specific network, when LTDHN maximum supply temperature can reach up to 65 °C. Two direct connection options are compared: a mixing shunt and 3-pipe connection shunt. Technical and economic aspects of this solution are analysed, including heat and electricity consumption, water flow rate and pressure, as well as additional investments and heating costs. The most feasible connecting option is compared with reference option applying exergy analysis. Particular emphasis is placed on assessing the decrease in the HTDHN return temperature caused by the integration of the LTDHN. The impact of the temperature decrease on the HTDHN is evaluated, including reduction of heat transfer losses, increase in combined heat and power plants (CHP’s) heat and electricity generation efficiency, and flue gas condenser efficiency. Other parameters, such as fuel savings are calculated as well.

Keywords: Energy cascade; Return temperature; Urban areas; Flue gas condenser; CHP; Exergy; Low temperature district heating (search for similar items in EconPapers)
Date: 2020
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (23)

Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0360544220304114
Full text for ScienceDirect subscribers only

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:eee:energy:v:198:y:2020:i:c:s0360544220304114

DOI: 10.1016/j.energy.2020.117304

Access Statistics for this article

Energy is currently edited by Henrik Lund and Mark J. Kaiser

More articles in Energy from Elsevier
Bibliographic data for series maintained by Catherine Liu ().

 
Page updated 2025-03-19
Handle: RePEc:eee:energy:v:198:y:2020:i:c:s0360544220304114