An improved evaluation method for thermal performance of borehole heat exchanger

Changxing Zhang, Ping Chen, Yufeng Liu, Shicai Sun and Donggen Peng

Renewable Energy, 2015, vol. 77, issue C, 142-151

Abstract: Thermal performance of vertical U-pipe borehole heat exchanger (BHE) is an important research subject for the design and application of ground-coupled heat pump system (GCHPs). This paper presents an improved evaluation method for thermal performance of BHE based on analytical solution model, which is validated by comparing with duct storage system (DST) model and field experiment. Using the evaluation method, impacts of inlet fluid temperature, fluid flow rate and borehole depth on thermal performance of two types of U-pipe BHEs are studied. The study provides a good alternative of the experimental method for thermal performance test (TPT) and a useful thermal performance evaluation tool for BHEs in GCHPs.

Keywords: Thermal performance; Borehole heat exchanger; Inlet fluid temperature; Fluid flow rate; Borehole thermal resistance (search for similar items in EconPapers)
Date: 2015
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (10)

Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0960148114008416
Full text for ScienceDirect subscribers only

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:eee:renene:v:77:y:2015:i:c:p:142-151

DOI: 10.1016/j.renene.2014.12.015

Access Statistics for this article

Renewable Energy is currently edited by Soteris A. Kalogirou and Paul Christodoulides

More articles in Renewable Energy from Elsevier
Bibliographic data for series maintained by Catherine Liu ().

 
Page updated 2025-03-19
Handle: RePEc:eee:renene:v:77:y:2015:i:c:p:142-151