A Liquid Desiccant Enhanced Two Stage Evaporative Cooling System—Development and Performance Evaluation of a Test Rig

M. Mujahid Rafique, Shafiqur Rehman, Luai M. Alhems and Muhammad Ali Shakir
Additional contact information
M. Mujahid Rafique: Department of Mechanical Engineering, King Fahd University of Petroleum and Minerals, Dhahran 31261, Saudi Arabia
Shafiqur Rehman: Center for Engineering Research, Research Institute, King Fahd University of Petroleum and Minerals, Dhahran 31261, Saudi Arabia
Luai M. Alhems: Center for Engineering Research, Research Institute, King Fahd University of Petroleum and Minerals, Dhahran 31261, Saudi Arabia
Muhammad Ali Shakir: Department of Mechanical Engineering, University College of Engineering and Technology, University of Sargodha, Sargodha 40100, Pakistan

Energies, 2017, vol. 11, issue 1, 1-17

Abstract: Desiccant technology is found to be a good alternative to conventional cooling systems. It can provide better thermal comfort under hot and humid climatic conditions. The major component of a liquid desiccant cooling system is the desiccant dehumidifier which controls the latent cooling load. In this paper, a newly developed liquid desiccant enhanced evaporative cooling system has been tested experimentally. The effects of ambient conditions and other parameters on the performance of the system are investigated. The system performance curves which help to determine the air outlet conditions and coefficient of performance (COP) of the system are drawn for a wide range of ambient air humidity ratios (0.010–0.026 kg/kg), ambient air temperature (25–40 °C), process air flow rate (1.5–8.0 kg/m 2 ·s), regeneration air flow rate (1.5–4.5 kg/m 2 ·s), and regeneration temperature (55–85 °C). The results showed that better supply air conditions are achieved for hot and humid climatic conditions with effectiveness of the system largely dependent on process and regeneration air flow rates, regeneration temperature, and humidity ratio of process air. The dehumidification performance is increased by 62% for a change of ambient air humidity ratio from 0.01 to 0.025 kg/kg. The thermal coefficient of performance improved by 50% for the above variation in humidity ratio. This shows that such thermally activated systems are feasible options for hot and humid climatic conditions as indicated by better performance under these conditions.

Keywords: liquid desiccant; evaporative cooler; air conditioning; rotary dehumidifier; sustainable development (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2017
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/11/1/72/pdf (application/pdf)
https://www.mdpi.com/1996-1073/11/1/72/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:11:y:2017:i:1:p:72-:d:124810

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-24
Handle: RePEc:gam:jeners:v:11:y:2017:i:1:p:72-:d:124810