Experimental Study on the Heat Release Operational Characteristics of a Soil Coupled Ground Heat Exchanger with Assisted Cooling Tower
Weibo Yang,
Binbin Yang and
Rui Xu
Additional contact information
Weibo Yang: School of Hydraulic, Energy and Power Engineering, Yangzhou University, Yangzhou 225127, Jiangsu, China
Binbin Yang: School of Hydraulic, Energy and Power Engineering, Yangzhou University, Yangzhou 225127, Jiangsu, China
Rui Xu: School of Hydraulic, Energy and Power Engineering, Yangzhou University, Yangzhou 225127, Jiangsu, China
Energies, 2018, vol. 11, issue 1, 1-17
Abstract:
Hybrid ground source heat pump systems (HGSHPS) with assisted cooling towers is one of the most efficient cooling and heating technologies for buildings with cooling-dominated loads. For the system, the coupled heat release mode between the ground heat exchanger (GHE) and cooling tower is vital for underground soil temperature recovery characteristics and system operation performance. In order to obtain the heat release operation characteristics with different coupled modes of the GHE and cooling tower, a set of multi-functional heat release experimental systems of soil coupled GHE with assisted cooling tower was constructed. The experimental investigations on the system heat release operation characteristics operated in the separate GHE heat release mode, combination heat release mode and day and night alternate heat release mode were undertaken based on the experimental system. The results show that for the separate GHE heat release mode, the heat release rate of GHE rises rapidly during the first two hours of operation, then, gradually tends to be steady, and the soil excess temperatures at various depths gradually rise with time. For the combination heat release mode with continuous operation of cooling tower, in view of reducing soil heat accumulation and accelerating soil temperature recovery, it is more conducive to the heat release by opening the cooling tower on sunny days. For the combination heat release mode with intermittent operation of cooling tower, when the total time ratio of cooling tower running to stop is constant, the intermittent time is longer, the better the effect of soil temperature recovery. Additionally, the soil temperature recovery rate can be improved greatly by the release heat operation of cooling tower during night, and the longer the cooling tower runs, the closer the soil temperature is to the initial temperature.
Keywords: hybrid-ground source heat pump system; cooling tower; combination heat release mode; day and night alternate heat release mode (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2018
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)
Downloads: (external link)
https://www.mdpi.com/1996-1073/11/1/90/pdf (application/pdf)
https://www.mdpi.com/1996-1073/11/1/90/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:11:y:2018:i:1:p:90-:d:125006
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().