Load Distribution of Semi-Central Evaporative Cooling Air-Conditioning System Based on the TRNSYS Platform
Ji Li,
Yuanwei Liu,
Ruixue Zhang,
Zhijian Liu,
Wei Xu,
Biao Qiao and
Xiaomei Feng
Additional contact information
Ji Li: Institute of Building Environment and Energy, China Academy of Building Research, Beijing 100013, China
Yuanwei Liu: Department of Power Engineering, North China Electric Power University, Baoding 071003, China
Ruixue Zhang: Institute of Building Environment and Energy, China Academy of Building Research, Beijing 100013, China
Zhijian Liu: Department of Power Engineering, North China Electric Power University, Baoding 071003, China
Wei Xu: Institute of Building Environment and Energy, China Academy of Building Research, Beijing 100013, China
Biao Qiao: Institute of Building Environment and Energy, China Academy of Building Research, Beijing 100013, China
Xiaomei Feng: Institute of Building Environment and Energy, China Academy of Building Research, Beijing 100013, China
Energies, 2018, vol. 11, issue 5, 1-15
Abstract:
Evaporative cooling is a green, energy-efficient cooling technology adopted in hot and dry regions, which has wider application in the field of air-conditioning systems. Outdoor meteorological parameters have a great influence on the operation mode and control strategy of evaporative cooling air-conditioning systems, and the system load distribution and system configuration will be affected. This paper aims at investigating the load distribution of semi-central evaporative cooling air-conditioning systems under the condition of hourly outdoor meteorological parameters. Firstly, this paper introduced the design partition, operation mode, controlling strategy and load distribution method on semi-central evaporative cooling air-conditioning system. Then, taking an office building in Lanzhou (China) as an example, the evaporative cooling air-conditioning system was divided into five regions and the load distribution was simulated by TRNSYS (The Transient Energy System Simulation Tool) under the condition of hourly outdoor meteorological parameters. Finally, the results have shown that the evaporative cooling air-conditioning system can provide 25.46% of the building loads, which was of great significance to reduce the energy consumption of air-conditioning system.
Keywords: semi-central evaporative cooling air-conditioning system; design partition; operation mode; controlling strategy; load distribution (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2018
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)
Downloads: (external link)
https://www.mdpi.com/1996-1073/11/5/1186/pdf (application/pdf)
https://www.mdpi.com/1996-1073/11/5/1186/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:11:y:2018:i:5:p:1186-:d:145172
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().