Comparison of Laboratory and Computational Models of Selected Thermal-Technical Properties of Constructions Systems Based on Wood
Jozef Švajlenka,
Mária Kozlovská,
František Vranay,
Terézia Pošiváková and
Miroslava Jámborová
Additional contact information
Jozef Švajlenka: Laboratory of Construction Technology and Management, Department of Construction Technology, Economy and Management, Faculty of Civil Engineering, Technical University of Košice, 042 00 Košice, Slovakia
Mária Kozlovská: Department of Construction Technology, Economy and Management, Faculty of Civil Engineering, Technical University of Košice, 0420 00 Košice, Slovakia
František Vranay: Laboratory of Building Construction, Department of Building Construction, Faculty of Civil Engineering, Technical University of Košice, 0420 00 Košice, Slovakia
Terézia Pošiváková: Department of the Environment, Veterinary Legislation and Economy, University of Veterinary Medicine and Pharmacy in Košice, 041 81 Košice, Slovakia
Miroslava Jámborová: Department of Process and Environmental Engineering, Faculty of Mechanical Engineering, Institute of Power and Process Engineering, Technical University of Košice, 042 00 Košice, Slovakia
Energies, 2020, vol. 13, issue 12, 1-15
Abstract:
Energy-efficient buildings, sustainable buildings, smart buildings, nearly zero-energy buildings, passive and active buildings are construction concepts widely recognised as setting the latest trends. The purpose of their design is to create an optimal thermal microclimate by means of heat flows that are either formed within it or enter into it. This research paper presents an analysis of the measurements of the density of heat flows, their spread in building constructions, all of which is examined in laboratory conditions and confronted with calculation models. The hypothesis of this research is to confirm or refute whether the computational models match the laboratory simulations in terms of thermal-technical parameters. The research uses a methodology designed for examining building constructions under virtually stable conditions. Two variants of external sandwich walls based on prefab cross laminated timber panels (variant A) and structural insulated panel (variant B) were proposed as the subject of the study. Both variants were subjected to research in laboratory conditions and computational simulations. For the sake of comparison, the calculation simulations that manufacturers of wood construction systems typically declare were also performed. The results of the analyses show significant differences between the theoretical or declared parameters and the values measured in laboratory conditions (7.5–32.6%). The deviations of the experimental measurements from the calculated or declared parameters were not as significant for variant A as they were for variant B. These findings show that for these analysed sandwich structures based on wood, it is not always possible to reliably declare calculated values of thermal-technical parameters. The publication is also a contribution to the current needs in the field of heating technology in terms of sustainability and the quality of internal environments.
Keywords: cross laminated timber; CLT; energy; prefab construction; structural insulated panel; SIPS; thermal; wood (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2020
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/13/12/3127/pdf (application/pdf)
https://www.mdpi.com/1996-1073/13/12/3127/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:13:y:2020:i:12:p:3127-:d:372406
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().