Modeling of a CPV/T-ORC Combined System Adopted for an Industrial User
Carlo Renno,
Fabio Petito,
Diana D’Agostino and
Francesco Minichiello
Additional contact information
Carlo Renno: Department of Industrial Engineering, University of Salerno, Via Giovanni Paolo II, 132, 84084 Fisciano (Salerno), Italy
Fabio Petito: Department of Industrial Engineering, University of Salerno, Via Giovanni Paolo II, 132, 84084 Fisciano (Salerno), Italy
Diana D’Agostino: Department of Industrial Engineering, University of Naples “Federico II”, Piazzale Tecchio 80, 80125 Naples, Italy
Francesco Minichiello: Department of Industrial Engineering, University of Naples “Federico II”, Piazzale Tecchio 80, 80125 Naples, Italy
Energies, 2020, vol. 13, issue 13, 1-17
Abstract:
The increasing energy demand encourages the use of photovoltaic solar systems coupled to organic rankine cycle (ORC) systems. This paper presents a model of an ORC system coupled with a concentrating photovoltaic and thermal (CPV/T) system. The CPV/T-ORC combined system, described and modeled in this paper, is sized to match the electrical load of a medium industrial user located in the South of Italy. A line-focus configuration of the CPV/T system, constituted by 16 modules with 500 triple-junction cells, is adopted. Different simulations have been realized evaluating also the direct normal irradiance (DNI) by means of the artificial neural network (ANN) and considering three input condition scenarios: Summer, winter, and middle season. Hence, the energy performances of the CPV/T-ORC system have been determined to evaluate if this integrated system can satisfy the industrial user energy loads. In particular, the peak power considered for the industrial machines is about 42 kW while other electrical, heating or cooling loads require a total peak power of 15 kW; a total electric average production of 7500 kWh/month is required. The annual analysis shows that the CPV/T-ORC system allows satisfying 100% of the electric loads from April to September; moreover, in these months the overproduction can be sold to the network or stored for a future use. The covering rates of the electrical loads are equal to 73%, 77%, and 83%, respectively for January, February, and March and 86%, 93%, and 100%, respectively for October, November, and December. Finally, the CPV/T-ORC combined system represents an ideal solution for an industrial user from the energy point of view.
Keywords: concentrating photovoltaic and thermal system; line-focus configuration; organic rankine cycle; industrial application (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2020
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)
Downloads: (external link)
https://www.mdpi.com/1996-1073/13/13/3476/pdf (application/pdf)
https://www.mdpi.com/1996-1073/13/13/3476/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:13:y:2020:i:13:p:3476-:d:380682
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().