Evaluation of Suitable Areas to Introduce a Closed-Loop Ground Source Heat Pump System in the Case of a Standard Japanese Detached Residence
Gaurav Shrestha,
Mayumi Yoshioka,
Hikari Fujii and
Youhei Uchida
Additional contact information
Gaurav Shrestha: Renewable Energy Research Center, National Institute of Advanced Industrial Science and Technology, 2-2-9 Machiikedai, Koriyama 963-0298, Japan
Mayumi Yoshioka: Geological Survey of Japan, National Institute of Advanced Industrial Science and Technology, 1-1-1 Higashi, Tsukuba, Ibaraki 305-8567, Japan
Hikari Fujii: Graduate School of International Resource Sciences, Akita University, 1-1 Tegatagakuencho, Akita 010-8502, Japan
Youhei Uchida: Renewable Energy Research Center, National Institute of Advanced Industrial Science and Technology, 2-2-9 Machiikedai, Koriyama 963-0298, Japan
Energies, 2020, vol. 13, issue 17, 1-15
Abstract:
Evaluation of appropriate areas to introduce a closed-loop ground-source heat pump (GSHP) system in the case of a standard detached residence was conducted in Akita Plain, Japan. Depth of borehole heat exchanger (BHE) required to use a GSHP system was taken as the suitability index, which is simpler for the general public to understand and to promote the system. Heating and cooling loads of the standard size detached residence were calculated based on the 2013 Energy Conservation Standard. To estimate BHE depths and estimate a suitable area, identical 3D BHE models were constructed at 30 points in the plain. Required BHE depths were determined by performing heat exchange simulations at each location using the calculated loads and heat exchange rates. A suitability map showing distribution of the required BHE depths was prepared. BHE depths were shorter in the north-western area compared to the other parts, implying that the coastal lowlands in this area are more suitable for closed-loop system in the standard detached residences in terms of heat exchange performance as well as the cost reduction. Thickly distributed Quaternary System with higher thermal conductivity is contributing to shorter BHE depths. The suitability map is effective to adopt potential areas for the system installation in the standard detached Japanese residences.
Keywords: ground source heat pump system; detached residence; borehole heat exchanger depth; suitable areas; Japan (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2020
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (2)
Downloads: (external link)
https://www.mdpi.com/1996-1073/13/17/4294/pdf (application/pdf)
https://www.mdpi.com/1996-1073/13/17/4294/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:13:y:2020:i:17:p:4294-:d:401217
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().