A Novel Approach to the Analysis of Thermal Response Test (TRT) with Interrupted Power Input
Jin Luo,
Yuhao Zhang,
Jiasheng Tuo,
Wei Xue,
Joachim Rohn and
Sebastian Baumgärtel
Additional contact information
Jin Luo: Faculty of Engineering, China University of Geosciences (Wuhan), Wuhan 430074, China
Yuhao Zhang: Faculty of Engineering, China University of Geosciences (Wuhan), Wuhan 430074, China
Jiasheng Tuo: China Electronic Research Institute of Engineering Investigations and Design, No. 218, Youyi East Road, Xi’an 710054, China
Wei Xue: Faculty of Engineering, China University of Geosciences (Wuhan), Wuhan 430074, China
Joachim Rohn: Geozentrum Nordbayern, Friedrich-Alexander-University Erlangen-Nuremberg, Schlossgarten 5, 91054 Erlangen, Germany
Sebastian Baumgärtel: Geozentrum Nordbayern, Friedrich-Alexander-University Erlangen-Nuremberg, Schlossgarten 5, 91054 Erlangen, Germany
Energies, 2020, vol. 13, issue 19, 1-14
Abstract:
The quality of measuring datasets of the thermal response test (TRT) significantly influences the interpretation of borehole thermal parameters (BTP). A thermal response test with an unstable power input may induce an unacceptable error in the estimation of the borehole thermal parameters. This paper proposes a novel approach to treat the dataset with interrupted power input. In this approach, the test records were segmented into several subsections with a constant time interval of 100 min, 60 min, and 30 min, separately. The quality of each data section was assessed and analyzed. Then, two algorithms, including the continuous algorithm and semi-superposition algorithm, were developed. The results estimated by the linear source model (LSM) were compared with one Thermal response test datasets with a stable power input at the same testing site. It shows that the effects of power interruption during the test can be effectively mitigated by deploying both the continuous and semi-superposition methods. The lowest deviation of the calculated thermal conductivity to a thermal response test with stable power input was 2.8% in the continuous method and 0.9% using the semi-superposition method. Thus, the proposed approaches are effective measures to mitigate the effects of interrupted power input on the interpretation of the thermal properties of the ground.
Keywords: thermal response test (TRT); interrupted power input; measuring outputs; borehole thermal parameters (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2020
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)
Downloads: (external link)
https://www.mdpi.com/1996-1073/13/19/5033/pdf (application/pdf)
https://www.mdpi.com/1996-1073/13/19/5033/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:13:y:2020:i:19:p:5033-:d:418729
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().