Cross-seasonal Experimental Study on the Comprehensive Performance of C-Si PV Window

Wei Zhang, Wei Wang, Lingzhi Xie, Hao Tian, Mo Chen, Zihao Li and Jianhui Li
Additional contact information
Wei Zhang: College of Architecture and Environment, Sichuan University, Chengdu 610065, China
Wei Wang: College of Architecture and Environment, Sichuan University, Chengdu 610065, China
Lingzhi Xie: Institute of New Energy and Low-carbon Technology, Sichuan University, Chengdu 610065, China
Hao Tian: College of Architecture and Environment, Sichuan University, Chengdu 610065, China
Mo Chen: College of Architecture and Environment, Sichuan University, Chengdu 610065, China
Zihao Li: College of Architecture and Environment, Sichuan University, Chengdu 610065, China
Jianhui Li: College of Architecture and Environment, Sichuan University, Chengdu 610065, China

Energies, 2020, vol. 13, issue 21, 1-26

Abstract: PV windows can potentially produce electricity, reduce the air-conditioning load, and provide natural light. Cross-seasonal experimental tests for long period could eliminate the gap between real outdoor test and simulation estimation. In this research, the lighting-thermal-electricity performance of high-efficiency c-silicon PV windows was tested, and the improvement has been put forward according to the conditions. The long-term experiment was conducted cross different seasons, including summer, autumn, and winter seasons. The highest average power generation, 50W/m 2 , could be found in autumn. The average outside surface temperature of the PV window would reach 48 °C in sunny days in the autumn, which was higher than other seasons. Although the c-Si PV window maybe block the partial daylighting, the daylighting requirement still could be satisfied with the most days. Furthermore, the average Useful Daylight Illuminance was the highest in summer up to 0.79, and the average illumination uniform could be achieved at a high level in all seasons. For the improvement suggestions, some measures could be taken to reduce the indoor cooling load in summer. During winter, appropriate inner shading measures might be taken to prevent excessive illumination in the building, and allow the electricity and thermal performance of PV window.

Keywords: C-Si; PV window; lighting-thermal-electricity performance; cross-seasonal test (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2020
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
https://www.mdpi.com/1996-1073/13/21/5684/pdf (application/pdf)
https://www.mdpi.com/1996-1073/13/21/5684/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:13:y:2020:i:21:p:5684-:d:437774

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:13:y:2020:i:21:p:5684-:d:437774