Computational Prediction of Susceptibility to Biofilms Growth: Two-Dimensional Analysis of Critical Construction Details
Václav Kočí,
Jan Kočí,
Jiří Maděra,
Jaroslav Žák and
Robert Černý
Additional contact information
Václav Kočí: Department of Materials Engineering and Chemistry, Faculty of Civil Engineering, Czech Technical University in Prague, Thákurova 7/2077, 166 29 Prague 6, Czech Republic
Jan Kočí: Department of Materials Engineering and Chemistry, Faculty of Civil Engineering, Czech Technical University in Prague, Thákurova 7/2077, 166 29 Prague 6, Czech Republic
Jiří Maděra: Department of Materials Engineering and Chemistry, Faculty of Civil Engineering, Czech Technical University in Prague, Thákurova 7/2077, 166 29 Prague 6, Czech Republic
Jaroslav Žák: Institute of Technology and Business in České Budějovice, Okružní 517/10, 370 01 České Budějovice, Czech Republic
Robert Černý: Department of Materials Engineering and Chemistry, Faculty of Civil Engineering, Czech Technical University in Prague, Thákurova 7/2077, 166 29 Prague 6, Czech Republic
Energies, 2020, vol. 13, issue 2, 1-17
Abstract:
Retrofitting of historical and traditional buildings is an effective thermal protection measure. The presence of thermal insulation in the composition of building envelopes might, however, bring some shortages due to a decrease of exterior surface temperatures or possible water vapor condensation. These shortages can improve living conditions for various microorganisms on the exterior surfaces, especially in the case of interior thermal insulation systems that are typical with thermal bridges and thus supply the surface with heat to a greater extent. This paper, therefore, aims at the investigation of hygrothermal conditions in selected critical construction details and evaluates the results from the point of view of potential biofilms growth. Two-dimensional modeling of coupled heat and moisture is applied and the hygrothermal patterns are evaluated based on an adjusted isopleth growth model. The results showed that the duration of favorable conditions for biofilms growth is relatively low, accounting for less than 180 h in the worst-case scenario. It means the exterior surfaces of historical buildings provided with interior thermal insulation systems are not threatened by biofilms growth. Anyway, other negative aspects have been revealed that should be treated individually. Possible wood decay or increased hygrothermal straining are the typical examples in that respect.
Keywords: biofilms growth; computational modeling; hygrothermal patterns; brick masonry; interior thermal insulation; climatic data; mineral wool; wood fiber board (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2020
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)
Downloads: (external link)
https://www.mdpi.com/1996-1073/13/2/293/pdf (application/pdf)
https://www.mdpi.com/1996-1073/13/2/293/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:13:y:2020:i:2:p:293-:d:306118
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().