Analysis of Metal Oxide Varistor Arresters for Protection of Multiconductor Transmission Lines Using Unconditionally-Stable Crank–Nicolson FDTD
Erika Stracqualursi,
Rodolfo Araneo,
Giampiero Lovat,
Amedeo Andreotti,
Paolo Burghignoli,
Jose Brandão Faria and
Salvatore Celozzi
Additional contact information
Erika Stracqualursi: Department of Astronautical, Electrical and Energy Engineering, University of Rome “La Sapienza”, via Eudossiana, 18, 00184 Rome, Italy
Rodolfo Araneo: Department of Astronautical, Electrical and Energy Engineering, University of Rome “La Sapienza”, via Eudossiana, 18, 00184 Rome, Italy
Giampiero Lovat: Department of Astronautical, Electrical and Energy Engineering, University of Rome “La Sapienza”, via Eudossiana, 18, 00184 Rome, Italy
Amedeo Andreotti: Electrical Engineering Department, University Federico II of Napoli, 80125 Napoli, Italy
Paolo Burghignoli: Department of Information Engineering, Electronics and Telecommunications, University of Rome “Sapienza”, via Eudossiana, 18, 00184 Rome, Italy
Jose Brandão Faria: Instituto de Telecomunicações, Instituto Superior Técnico—Universidade de Lisboa, 1049-001 Lisboa, Portugal
Salvatore Celozzi: Department of Astronautical, Electrical and Energy Engineering, University of Rome “La Sapienza”, via Eudossiana, 18, 00184 Rome, Italy
Energies, 2020, vol. 13, issue 8, 1-19
Abstract:
Surge arresters may represent an efficient choice for limiting lightning surge effects, significantly reducing the outage rate of power lines. The present work firstly presents an efficient numerical approach suitable for insulation coordination studies based on an implicit Crank–Nicolson finite difference time domain method; then, the IEEE recommended surge arrester model is reviewed and implemented by means of a local implicit scheme, based on a set of non-linear equations, that are recast in a suitable form for efficient solution. The model is proven to ensure robustness and second-order accuracy. The implementation of the arrester model in the implicit Crank–Nicolson scheme represents the added value brought by the present study. Indeed, its preserved stability for larger time steps allows reducing running time by more than 60 % compared to the well-known finite difference time domain method based on the explicit leap-frog scheme. The reduced computation time allows faster repeated solutions, which need to be looked for on assessing the lightning performance (randomly changing, parameters such as peak current, rise time, tail time, location of the vertical leader channel, phase conductor voltages, footing resistance, insulator strength, etc. would need to be changed thousands of times).
Keywords: FDTD; Metal Oxide Varistors Arresters; transmission lines; protection (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2020
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)
Downloads: (external link)
https://www.mdpi.com/1996-1073/13/8/2112/pdf (application/pdf)
https://www.mdpi.com/1996-1073/13/8/2112/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:13:y:2020:i:8:p:2112-:d:349814
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().