Direct Analytical Modeling for Optimal, On-Design Performance of Ejector for Simulating Heat-Driven Systems
Fahid Riaz,
Fu Zhi Yam,
Muhammad Abdul Qyyum,
Muhammad Wakil Shahzad,
Muhammad Farooq,
Poh Seng Lee and
Moonyong Lee
Additional contact information
Fahid Riaz: Department of Mechanical Engineering, National University of Singapore, Singapore 117575, Singapore
Fu Zhi Yam: Department of Mechanical Engineering, National University of Singapore, Singapore 117575, Singapore
Muhammad Abdul Qyyum: School of Chemical Engineering, Yeungnam University, Gyeongsan 712-749, Korea
Muhammad Wakil Shahzad: Department of Mechanical and Construction Engineering, Northumbria University, Newcastle Upon Tyne NE1 8ST, UK
Muhammad Farooq: Department of Mechanical Engineering, University of Engineering and Technology Lahore, Lahore 54000, Pakistan
Poh Seng Lee: Department of Mechanical Engineering, National University of Singapore, Singapore 117575, Singapore
Moonyong Lee: School of Chemical Engineering, Yeungnam University, Gyeongsan 712-749, Korea
Energies, 2021, vol. 14, issue 10, 1-21
Abstract:
This paper describes an ejector model for the prediction of on-design performance under available conditions. This is a direct method of calculating the optimal ejector performance (entrainment ratio or ER) without the need for iterative methods, which have been conventionally used. The values of three ejector efficiencies used to account for losses in the ejector are calculated by using a systematic approach (by employing CFD analysis) rather than the hit and trial method. Both experimental and analytical data from literature are used to validate the presented analytical model with good agreement for on-design performance. R245fa working fluid has been used for low-grade heat applications, and Engineering Equation Solver (EES) has been employed for simulating the proposed model. The presented model is suitable for integration with any thermal system model and its optimization because of its direct, non-iterative methodology. This model is a non-dimensional model and therefore requires no geometrical dimensions to be able to calculate ejector performance. The model has been validated against various experimental results, and the model is employed to generate the ejector performance curves for R245fa working fluid. In addition, system simulation results of the ejector refrigeration system (ERS) and combined cooling and power (CCP) system have been produced by using the proposed analytical model.
Keywords: ejector; low-grade heat; R245fa; simulation; CFD; heat recovery; energy; thermal; system (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2021
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)
Downloads: (external link)
https://www.mdpi.com/1996-1073/14/10/2819/pdf (application/pdf)
https://www.mdpi.com/1996-1073/14/10/2819/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:14:y:2021:i:10:p:2819-:d:554526
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().