Shading and Masking of PV Collectors on Horizontal and Sloped Planes Facing South and North—A Comparative Study
Saeed Swaid,
Joseph Appelbaum and
Avi Aronescu
Additional contact information
Saeed Swaid: School of Electrical Engineering, Tel Aviv University, 69978 Tel Aviv, Israel
Joseph Appelbaum: School of Electrical Engineering, Tel Aviv University, 69978 Tel Aviv, Israel
Avi Aronescu: School of Electrical Engineering, Tel Aviv University, 69978 Tel Aviv, Israel
Energies, 2021, vol. 14, issue 13, 1-15
Abstract:
With the increase in PV system installations, the available free land and rooftops for these systems may become scarcer, and therefore sloped fields facing the north may be utilized for that purpose. In deployments of PV collectors in multiple rows, either on horizontal or sloped planes, the second and subsequent rows are subject to two effects: shading and masking. Both effects reduce the electric energy generated by the PV systems. Multiple rows of collectors are deployed on horizontal planes and on sloped planes facing south, and literature on the topic has been published. No literature deals analytically with deployments of PV fields on north-facing slopes in the northern hemisphere, to the best of our knowledge. The present study develops explicit analytical expressions for the shadow height and length cast on a collector row by a row in front in multiple-row PV systems installed on slopes facing north. In addition, analytical expressions are developed for row spacing and sky view factors, altogether leading consequently to the determination of shading and masking losses. Having the developed expressions, a comparison was made between PV deployments on north-facing sloped planes to PV deployments on horizontal and south-facing slopes regarding shading and masking losses. The main finding is that the percentage of masking losses (diffuse radiation) may exceed the percentage of shading losses (beam radiation) in PV fields. At the local site 32 ? N , collector inclination angle ? = 25 ? and sloped-plane ? = 10 ? , for example, the percentage of masking losses for a horizontal plane is 6.90%; for a sloped plane facing south, the losses are 5.39%, and for a sloped plane facing north, the losses are 6.86%. In comparison to the masking losses, the percentage of shading losses for the horizontal plane is 0.83%; for the sloped plane facing south, the losses are 0.42%, and for the sloped plane facing north, the losses are 1.37%.
Keywords: row shading; row masking; shading losses; masking losses; horizontal and sloped plane PV deployments (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2021
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (2)
Downloads: (external link)
https://www.mdpi.com/1996-1073/14/13/3850/pdf (application/pdf)
https://www.mdpi.com/1996-1073/14/13/3850/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:14:y:2021:i:13:p:3850-:d:582690
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().